Normal operation
Installation, use and maintenance manual – TS 2000
15
6
5 NORMAL OPERATION
This section is for the end user.
The operation of the TS 2000 gas-red convectors is con-
trolled by the control knob on the appliance.
5.1 WARNINGS
General warnings
Prior to using the appliance carefully read the
warnings in Chapter III.1
p. 4
, providing impor-
tant information on regulations and on safety.
First startup by TAC
First start-up may exclusively be carried out by a
Robur TAC (Chapter 6
p.16
).
Do not obstruct the lower grille or the upper air
outlet grille.
During operation of the appliance, pay atten-
tion to the upper grille, which is hot.
Do not obstruct the air intake and ue gas ex-
haust ducts located outside the room.
5.2 CONTROL KNOB
Figure5.1 Control knob
A Piezoelectric ignition button
B Control knob
1 Minimum temperature
7 Maximum temperature
Position for ignition (pilot ame)
Position for switching o
A
B
5.3 SWITCH ON AND OFF
5.3.1 Switching on
Figure 5.1
p.15
.
1. Open the gas valve.
2. Turn the control knob to position .
3. Press the knob fully.
4. While keeping the knob pressed down, press button A
on the piezo igniter of the pilot ame.
5. Wait a few seconds then release the knob. The pilot
ame will remain lit.
The rst ignition can be dicult due to the air con-
tained in the gas supply pipe.
6. Turn the control knob counterclockwise to increase
the room temperature and clockwise to decrease it.
7. Position 7 corresponds to the highest achievable room
temperature, position 1 corresponds to the lowest
room temperature.
The indication on the thermostat knob is purely
indicative. The value of the set temperature de-
pends on the type of room in which the appliance
is installed. A relationship between the thermostat
position and the actual room temperature can be
obtained by measuring the room temperature at a
given thermostat setting.
In case of accidental or intentional switch-o wait
about 3 minutes before a new ignition attempt so
that unburnt gas can escape from the combustion
chamber.
5.3.2 Switching o
Figure 5.1
p.15
.
1. To switch o the appliance, turn the knob to the
position. In this way only the pilot ame will remain lit.
2. In case of prolonged periods of inactivity (e.g. at the
end of the heating season), turn the knob to the
position. Then close the gas valve.