The display will now read the pre-infusion setting for key C:
After setting of key C please proceed setting key D (read out: 2 Espressos) and key
E (read out: 2 Coffees).
After this step continuing depressing key A the display reads:
Please disregard and press key A repetitiously until the display reads:
Probe sensitivity
The factory setting is “medium”. This setting is related to the conductivity of the
water. Setting the right sensitivity allows the correct function of the machine’s
automatic boiler level control system
The sensitivity of the probe can be set to:
Low = 150
Medium = 400
High = 1 M Ω
The next settings are:
Service cycles
This setting is 0000 (= disabled ex factory).
Boiler probe
Must be set to PRESSURE. Please do not change this setting. Depress A to go
ahead.
Boiler Pressure
1.0 Bar (Typical factory setting)
kP KI kD
9.5 0,15 10 (Please do not change these settings)
PID setting
2°C (Please do not change this setting).
Pre-Inf. ON sec
Coffee 1.0
Pre-Inf. OFF sec
Espresso 1.0