_____________________________________________________________________________________________
Subject to change without notice. 14
The display reads:
Key 1
Key 2
This means the machine is in normal operation mode.
Please proceed as follows to enter programming mode.
1. Keep Key 3 pressed for at least 5 seconds until display reads “Language”.
2. Press Key 1 or key 2 until the display reads the desired language.
3. Press Key 3 to confirm and to move to the next setting which is the
selection of “Water reservoir operation” or “hard plumbing operation”
of the machine.
4. Use Key 1 or Key 2 to program the desired operation and press Key 3 to
confirm and proceed to the next setting which is enabling or disabling the
heating of the hot water/steam boiler (“service boiler”).
5. The display will read “Service boiler heating: off” or “Service boiler
heating: on”. Use Key 1 or Key 2 to program the desired option and
confirm with Key 3. Please note that turning off the heating of the service
boiler means operating only in coffee dispensing mode (using the coffee
brew boiler only).
6. Use Key 1 or Key 2 to program the desired operation and press Key 3 to
confirm and proceed to the next step which is setting the coffee brew
boiler temperature. The factory setting is 105°C. The temperature can be
set within a range from 95°C to 115°C.
7. Use Key 1 or Key 2 to program the desired temperature and press Key 3 to
confirm and proceed to the next step which is setting the service boiler
pressure (hot water/steam boiler). The pressure can be set within a range
of 0.8 Bar to 1.3 Bar. Factory setting is 1.1 Bar.
8. Use Key 1 or Key 2 to program the desired operation and press Key 3 to
confirm. Now the display reads again
Brew boiler
Temperature 105 °C (or the pressure you set)
Important: For “operation” you must exit “programme” mode through the exit
screen only.:
Brew boiler
Temperature 105 °C (or the temperature you set)