DIGITAL COMMUNICATOR
• Phone line tone detection upon the automatic initiating the reporting to the central station;
• 2 separate accounts and individual communicator formats to identify each partition upon
transmission to “central station”;
• 2 individual programmable phone numbers for transmission to CS1 and to CS2;
• Alternate or Split (double) reporting to CS1 and to CS2;
• 1 FIFO buffer which storages up to 80 events for transmission to CS, without erasing the
old events in case of “CS1 and CS2 communication failed” event, if alternate reporting is selected;
• 2 FIFO buffers which storage up to 80 events each, for transmission to CS1 and to CS2,
without erasing the old events in case of “CS1 communication failed” event and/or “CS2
communication failed” event, if split (or double) reporting is selected;
• Adaptive algorithm to function with central stations which generate handshake
frequencies in any order and kiss-off time from 0.6 to 3 seconds;
• Many communicator formats - DTMF Ademco Contact ID and several 4x2 formats (10PPS,
20PPS, 40PPS and DTMF Ademco Express);
• Programmable data and handshake frequency and transmission speed in 4x2 format:
Ademco Express, 10PPS, 20PPS or 40PPS with parity/no parity, data of 1800 (or 1900) Hz and
handshake of 1400 (or 2300) Hz;
• Periodical test reporting (with steps of up to 255 minutes or hours, time adjustment of the
starting and either unconditionally reporting or only while armed status);
• Programmable reporting codes for “zone alarming”, “zone restore” and “zone bypassing”
(automatic “from swinger” or by the panel - during home arming periods, if the zones have the
attribute “stay” - and manually by the users);
• Programmable zone restore (the “zone restore event” is recorded either in real time for each
violated zone, when the violated zone “closed back”, or upon bell cut-off, for all zones that previously
triggered the alarm);
• Programmable reporting codes for Arming/Disarming/Ambush events, according to the user
code;
• Programmable reporting codes for system trouble situations: “Low battery voltage”, “Restore
battery voltage”, “AC power loss”, “AC power Restore”, “Bell Trouble” (upon disconnection or overload
on the siren),
“Bell trouble Restore” (Restore of disconnection or overload on the siren), “AUX
overload”, “AUX overload Restore”, “ System time and date Loss”, “System time and date
Reprogrammed”, “Keypad lockout”;
• Cancellation of reporting to CS may be performed only by installer.
UPLOAD/DOWNLOAD
• Several upload/download operations:
- Uploading the system parameters from control panel onto PC (actually, onto “EZcom
C62 Software”);
- Downloading the programming of system parameters from PC (actually, from “EZcom
C62 Software”) onto the control panel (PC programming using “EZcom C62 Software”);
- Uploading the event LOG from the control panel into the “EZcom C62 Software”
(actually, in a file);
- System time and date setting by PC (actually, by “EZcom C62 Software”);
- System (or partitions) arming/Disarming from PC (actually, by “EZcom C62 Software”);
- Zone bypassing by PC (actually, by “EZcom C62 Software”);
- PGM activation/deactivation by PC (only for PGM outputs defined as “mono-stable”, “bi-
stable” or “clock timer” types);
- Online visualization of the system/partitions status and troubles onto “EZcom C62
Software”;