EasyManua.ls Logo

ROEL CERBER C82 - User Manual

Default Icon
62 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
CERBER C52/C82
10/16-Zone LED Keypad Operated Alarm Control Panel
Installation and Programming Manual
March 2016/ version 3.0.

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the ROEL CERBER C82 and is the answer not in the manual?

Summary

INTRODUCTION

User Codes

Details on programmable user codes, their rights, and functions.

Installer Codes

Information about the installer's programming code and its access.

Digital Communicator

Features and functions of the digital communicator for reporting.

Zones

Configuration and attributes of the alarm system's zones.

KEYPADS

INSTALLING AND COMMISSIONING

Mounting the Panel

Instructions for selecting a location and mounting the main control panel.

Mounting the Keypad

Guidance on positioning and mounting the keypad near entry/exit doors.

Wiring

General guidelines and diagrams for connecting system components.

Connectors

Detailed explanation of the terminal connectors on the control panel PCB.

Commissioning

Procedure for initial setup and testing of the alarm system.

Reset to Default Procedure

Steps to restore the system to its factory default settings.

OPERATION

User Codes

Details on master and user codes, their capabilities, and programming.

Regular; Away Arming

Method for arming the system in away mode using a user code.

Instant Stay Arming

Arming mode for perimeter protection allowing users to remain inside.

Stay Arming

Arming mode for perimeter protection allowing users to remain inside with delayed entry.

Disarming & Deactivating an Alarm

Procedures for disarming the system and stopping active alarms.

System Trouble Displaying: [*][4] Command

How to check for system troubles using keypad commands and LED indicators.

Master Users Programming Menus

Selective Programming; Erasure of 01 to 30 user codes

Adding or deleting specific user codes and their access rights.

SYSTEM PARAMETERS PROGRAMMING

Installers Programming Code

How the installer uses their code to access system parameter programming.

Programming Sections

Overview of the numbered sections available for system parameter configuration.

SECTIONS [01]... [10];[16] (1 TO 10;16 ZONES DEFINING)

Programming zone characteristics like type and attributes.

ZONE TYPES

Defining the operational type for each alarm zone (e.g., delayed, instant).

ATTRIBUTES¹ set

Setting the primary attributes for each zone, like audible alarm or forced arming.

ATTRIBUTES² set

Configuring secondary zone attributes such as intellizone or tamper recognition.

SECTION [01] - DEFINING ZONE 1

Detailed steps for programming the characteristics of Zone 1.

SECTION [02] - DEFINING ZONE 2

Detailed steps for programming the characteristics of Zone 2.

SECTION [06] - DEFINING ZONE 6

Detailed steps for programming the characteristics of Zone 6.

SECTION [07] - DEFINING ZONE 7

Detailed steps for programming the characteristics of Zone 7.

SECTION [16] - DEFINING ZONE 16

Detailed steps for programming the characteristics of Zone 16.

SECTION [20] - 1 ST SET OF GENERAL SYSTEM OPTIONS

SECTION [27] - 4 TH SET OF GENERAL SYSTEM OPTIONS (TELEPHONE OPTIONS)

SECTION [28] - 5 TH SET OF GENERAL SYSTEM OPTIONS (DIGITAL COMMUNICATOR)

SECTION [30] - ENTRY DELAY 1; ENTRY DELAY 2 TIMERS

Entry Delay 1

Setting the first entry delay time for zones.

Entry Delay 2

Setting the second entry delay time for zones.

SECTION [32] - BURGLARY; FIRE BELL CUT-OFF TIMINGS

SECTION [35] - ACTIVATION TIME FOR PGM1 AND PGM2, DEFINED AS PULSE TYPE (001 TO 255 SECONDS)

SECTION [39] - PGM1 AND PGM2 TYPE PROGRAMMING

SECTION [40] - EVENT REPORTING REGARDING: ARMING BY USER; STAY ARMING BY USER; DISARMING BY USER; USER UNDER DURESS;, AUTO ARMING CANCELLATION;,, KEYPAD TAMPER ALARM;,, KEYPAD TAMPER RESTORE

SECTION [41] - EVENT REPORTING REGARDING: AUTO ZONE SHUTDOWN; ZONE BYPASSED; BURGLARY ALARM; TAMPER ALARM; PANIC ALARM; FIRE ALARM; MEDICAL EMERGENCY ALARM

SECTION [44] - EVENT REPORTING REGARDING: PARTIAL ARMING; FAIL TO AUTOARM; AC POWER FAILURE; BATTERY FAILURE; BELL TROUBLE; AUXILIARY SUPPLY TROUBLE; TIME & DATE INACCURATE

SECTION [45] - EVENT REPORTING REGARDING: AC POWER RESTORE; BATTERY VOLTAGE RESTORE; BELL TROUBLE RESTORE; AUXILIARY SUPPLY RESTORE; TIME & DATE REPROGRAMMED; PERIODICAL TEST REPORT

SECTION [46] - MOMENT FOR THE FIRST PERIODICAL TEST (HOUR:MINUTE)

SECTION [47] - INACTIVITY TIME” AFTER THAT THE SYSTEM; PARTITION A WILL AUTO ARM (HOUR & MINUTE)

SECTION [48] - INACTIVITY TIME

SECTION [49] - INSTALLERS CODE PROGRAMMING

Installers Code Programming

Procedure for changing the installer's default programming code.

SECTION [50] - MASTER CODE PROGRAMMING, PERFORMED BY INSTALLER

Master Code Programming

How the installer programs the master user code and its rights.

SECTION [51] - ACTIVATION MOMENT FOR PGM1 AS CLOCK TIMER (HOUR:MINUTE)

SECTION [52] - DEACTIVATION MOMENT FOR PGM1 AS CLOCK TIMER (HOUR:MINUTE)

SECTION [53] - ACTIVATION MOMENT FOR PGM2 AS CLOCK TIMER (HOUR:MINUTE)

SECTION [54] - DEACTIVATION MOMENT FOR PGM2 AS CLOCK TIMER” (HOUR:MINUTE)

SECTION [55] - AUTO ARMING MOMENT FOR SYSTEM; PARTITION A (HOUR:MINUTE)

SECTION [57] - AUTO ARMING MOMENT FOR PARTITION B (HOUR:MINUTE)

SECTION [58] - AUTO DISARMING MOMENT FOR PARTITION B (HOUR:MINUTE)

SECTION [59] - FIRST PANEL ACCOUNT FOR CS REPORTING

SECTION [61] - FIRST PHONE NUMBER FOR CS REPORTING

SECTION [62] - SECOND PHONE NUMBER FOR CS REPORTING

SECTION [65] - ONLINE DOWNLOAD (PC PROGRAMMING ACCEPTANCE)

TECHNICAL SPECIFICATIONS

ROEL CERBER C82 Specifications

General IconGeneral
Operating temperature-10°C to +55°C
Number of zones8
Communication interfaceRS-485
Storage temperature-20°C to 70°C
Number of outputs4