53
Note: the system / partition A will auto disarm only if the appropriate option was enabled by programming and if the
entered data was valid (the value for hour [hh] is between 0 and 23 and the value for minute [mm] is between 0 and
59).
SECTION [57] AUTO ARMING MOMENT FOR PARTITION B (HOUR:MINUTE)
Enter 2 groups of 2 digits, the first 2 digits for the hour (00 to 23) and the second 2 digits for
the minute (00 to 59); in this way will be set the daily moment when the partition B is arming
automatically.
The following sequence will be introduced:
|__|__||__|__| not programmed by default
The keypad buzzer will sound 3 beeps after the first 2-digit group and 6 beeps after the
second one. Then the panel exits the section and will wait for a new command to enter
another section.
To exit the „main programming menu”, press [#] key.
Note: the partition B will auto arm only if the appropriate option was enabled by programming and if the entered data
was valid (the value for hour [hh] is between 0 and 23 and the value for minute [mm] is between 0 and 59).
SECTION [58] AUTO DISARMING MOMENT FOR PARTITION B (HOUR:MINUTE)
Enter 2 groups of 2 digits, the first 2 digits for the hour (00 to 23) and the second 2 digits for
the minute (00 to 59); in this way will be set the daily moment when the partition B is
disarming automatically.
The following sequence will be introduced:
|__|__||__|__| not programmed by default
The keypad buzzer will sound 3 beeps after the first 2-digit group and 6 beeps after the
second one. Then the panel exits the section and will wait for a new command to enter
another section.
To exit the „main programming menu”, press [#] key.
Note: The partitions B will auto disarm only if the appropriate option was enabled by programming and if the entered
data was valid (the value for hour [hh] is between 0 and 23 and the value for minute [mm] is between 0 and 59).
SECTION [59] - FIRST PANEL ACCOUNT FOR CS REPORTING
Enter 4 digits (HEX digits may be used), which will stand for the first panel account.
The following sequence will be introduced:
[x][x][x][x] |F||F||F||F| by default
The keypad buzzer will sound 3 beeps after any digit entering and 6 beeps after entering of
the last one. Then the panel exits the section and will wait for a new command to enter
another section.
After any digit was pressed, programming of the first panel account may be canceled by
pressing the [#] key. After pressing the [#] key, the keypad buzzer will sound 6 confirmation
beeps, the system will keep the old value for the first panel account and the control panel will
go back within „main programming menu”
Note: the control panel will use the first panel account in order to identify the system / partition A to CS.
SECTION [60] - SECOND PANEL ACCOUNT FOR CS REPORTING
Enter 4 digits (HEX digits may be used), which will stand for the second panel account.
The following sequence will be introduced:
[x][x][x][x] |F||F||F||F| by default
The keypad buzzer will sound 3 beeps after any digit entering and 6 beeps after entering of
the last one. Then the panel exits the section and will wait for a new command to enter
another section.
After any digit was pressed, programming of the second panel account may be canceled by
pressing the [#] key. After pressing the [#] key, the keypad buzzer will sound 6 confirmation
beeps, the system will keep the old value for the second panel account and the control panel
will go back within „main programming menu”