SECTION [39] - PGM1 AND PGM2 TYPE PROGRAMMING
The system has 2 programmable outputs on the main board: PGM1 and PGM2.
These outputs are NPN transistors activated to the ground.
While system is within „main programming menu”, to set the type of programmable
outputs PGM1 and PGM2 select section [39] and then enter 2 groups of 2 digits
each:
|__|__| |__|__| |0D||0E| by default
The first group is setting the PGM1 type and the second group is setting the PGM2
type.
After the first 2 digits were entered, the keypad buzzer will sound 3 beeps and after the last 2
digits were entered, the keypad buzzer will sound 6 confirmation beeps and the panel exits
the section, waiting for a new command to enter another section.
Press [#] key instead of the 2 corresponding digits if the type of one of the programmable
outputs isn’t to be changed.
To exit the „main programming menu”, press [#] key.
[00] LATCH ON ALARM
The output goes to ground in alarm and is shut OFF when disarming.
[01] FOLLOW SYSTEM STATUS
The output goes to ground when arming and it is shut OFF when disarming.
[02] ON DURING ENTRY TIME
The output goes to ground during entry time.
[03] ON DURING EXIT DELAY
The output goes to ground during exit delay.
[04] SYSTEM TROUBLES
This output type goes to ON status (to ground) while there is at least a trouble in the system
(„AC power loss”, „low voltage on battery”, „fail to communicate event”, „BELL trouble”,
“phone line trouble”, „AUX trouble” or „system date and hour loss”).
[05] AUXILIARY SIREN
The output goes to ground while the siren is sounding.
[06] “SILENT” ALARM (WITHOUT SIREN)
The output goes to ground when any silent alarm is activated.
[07] PANIC
The output goes to ground when any panic alarm is activated (panic zone or by
simultaneously pressing [*]+[#] keys).
[08] FIRE
The output goes to ground when any fire alarm is activated or after simultaneously pressing
[7]+[9] keys.
[09] MEDICAL EMERGENCY
The output goes to ground when any medical emergency alarm is activated or after
simultaneously pressing [1]+[3] keys.
[0A] TAMPER
The output goes to ground when any tamper zone is activated.
[0B] PULSE ON PHONE LINE TROUBLE
Upon phone line trouble the output goes to ground for the time programmed in section [35].
[0C] MONO-STABLE
When the command [*][9] is entered, the output goes to ground for the time programmed in
section [35].
[0D] PULSE ON ARMING