SECTION [48] – „INACTIVITY TIME” AFTER THAT THE PARTITION B WILL AUTO ARM (HOUR & MINUTE)
Enter 2 groups of 2 digits; the first 2 digits for the number of hours (00 to 99) and the second
2 digits for the number of minutes (00 to 99) after that the partition B will auto arm if no
motion will be detected in the protected area.
The following sequence will be introduced:
|__|__||__|__| |03||00| by default (3 hours)
The keypad buzzer will sound 3 beeps after the first 2-digit group and 6 beeps after the
second one. Then the panel exits the section and will wait for a new command to enter
another section.
To exit the „main programming menu”, press [#] key.
Note: If in this section the 2 groups of 2 digits are set both with value 0, the partition B will try to auto arm after
every second if no activity was detected in the protected area.
SECTION [49] – INSTALLER’S CODE PROGRAMMING
While the panel is within the “main programming menu”, select section [49] in order to
program the installer’s code, then enter the following sequence:
[x][x][x][x], where [x][x][x][x] are the new 4 digits for the installer’s code.
While the system is section [49], the keypad LEDs’ status will be as follows:
Means the installer’s code is programmed and the control
panel is waiting for the first digit entering (the installer’s
code is always programmed).
One of the 2 to 4 zone LEDs
Means the installer’s code is programming and the control
panel is waiting for the corresponding digit.
1. The installer’s code programming may be skipped by [#] key pressing. After [#]
key pressing, the keypad buzzer will sound 6 confirmation beeps and the control panel will go
back within “main programming menu”.
2. In order to program the installer’s code, you should enter the following sequence
from the keypad:
[x][x][x][x], where [x][x][x][x] are the new 4 digits for the installer’s code.
2.1 After entering the first digit the zone 2 LED will blink. Means the control panel is
waiting for the second digit.
2.2. After entering second digit the zone 3 LED will blink. Means the control panel is
waiting for the third digit.
2.3. After entering third digit the zone 4 LED will blink. Means the control panel is
waiting for the fourth digit.
2.4. After any digit was pressed, installer’s code programming may be canceled by
[#] key pressing. After cancellation by [#] key pressing, the keypad buzzer will sound 6
confirmation beeps, the control panel will keep the old value for the installer’s code and then
will go back within “main programming menu”.
Note: Do not press [*] key while entering the digits of the installer’s code! The keypad buzzer will sound a long error
beep, will reject [*] key and will go back within “main programming menu”.
3. After entering the last digit of the installer’s code the keypad buzzer will sound 6
confirmation beeps and the control panel will go back within “main programming
menu”.
Notes: