5
- Online visualization of the bypassed, alarmed or open zones onto “EZcom C62
Software”.
• Programmable callback function with up to 3 attempts, automatic or manually activation
(manually activation may be performed by master or by installer);
• 400-event LOG with upload and visualizing possibility through the “EZcom C62 Software” and
optionally reported to CS;
• Option of automatic answers to PC calls, either after “double call” or after programmable
number of rings;
• Manually activation of communication with PC (PC download acceptance), performed by
master or by installer;
• Communication between PC and panel Cancellation, performed by master or by installer.
ZONES
• 6 End-of-line resistor zones, entirely programmable as delayed, instant, follower, 24 hour
burglary, fire, tamper, panic, medical emergency, arming/Disarming (keyswitch) or round type;
• 12 zone attributes, individually programmable as “audible/silent alarm”, “steady/pulsing siren”,
manually bypassing”, “auto shutdown”, “forced arming”, “chime function activating”, “stay”,
intellizone”, “sensor under test”, as well as individually selectable zone response time;
• “Zone bypassing” (automatic “from swinger” or by the panel - during home arming periods, if the
zones have the attribute “stay” - and manually by the users);
• 2 real partitions which can be armed/disarmed independently from each other – allowed by
user rights;
• Individually programmable exit and entry delay times for each partition – allowed by
programming;
Programmable alarm type: silent or audible and for the audible alarms steady or pulsing;
Individual siren timers for burglary and fire alarms;
PGM FUNCTIONS
2 programmable outputs, each with 31 options:Panic alarm latch, Fire alarm latch, Medical
emergency alarm latch, Latch on tamper alarm, Any alarm latch, “Pulsing siren, “Steady siren,
“silent alarm” latch, Follow system status (ON while system is armed / OFF while system is
disarmed), Entry delay, Exit delay, System troubles, Clock timer, Warning/confirmation
pulses, “Buzzer warnings during the warning round time, Pulse after exit delay, Pulse on arming,
Pulse on Disarming, Courtesy light, Pulse on round OK, Pulse on round failed
, Pulse on siren
troubles, Retriggerable mono-stable, Resetable mono-stable, Bi-stable and Pulse on alarm
triggered by each 1 to 6 zones”;
MONITORING OF SYSTEM TROUBLES
• Battery Voltage and AC power monitoring;
Siren monitoring (upon disconnection or overload);
“AUX overload” monitoring;
• Option of telephone line monitoring (TLM).
• Status of zone tampers (if enabled zone tamper recognition).
VOICE MESSAGES (SYNTHESIS SOUNDS) COMMUNICATOR
• Capability of response to the remote calls for system status interrogation (the system status
-armed/disarmed/alarm/”AC power loss” – will be reported by specific voice messages or by specific
synthesis sounds);
• Programmable options of responses to the remote calls for system status interrogation,
either after “double call” or after programmable number of rings;