46
OPTIONS for digital communicator:
zone LEDs ON OFF Remarks:
for the user numbers from 15 to 45
(in case of reporting in 4x2 formats)
Zone 5 LED
only while armed status
*
unconditionally periodical test reporting
Zone 6 LED
upon zone closure
*
upon bell cut-off zone restore
Note: The default programmed options are marked with *.
Presses [1] to [6] keys in order to turn the appropriate options activate/deactivate. The
corresponding LEDs will turn ON/OFF.
After setting these options, press [#] key to confirm. The keypad buzzer will sound 6
confirmation beeps and the panel exits the section, waiting for a new command to enter another
section or [#] key to exit the main programming menu.
Notes:
1. There is a safely switching between alternate and split reporting during the same transmission to CS, but switching format
types between Contact ID and 4x2 formats is still recommended to be performed without any active CS transmission.
2. In case the reporting to CS is programmed in this section as alternate, for control panel to initiate CS reporting, at least
one CS phone number must be programmed in [74] or [75] sections. If 1
-st
CS phone number is programmed in
section [74], the control panel will first try to report any event to this phone number. After the control panel takes the phone
line over for CS transmitting, it will wait 25 seconds for handshake receiving from CS (1
-st
CS phone number dialing is
included). In case 1
-st
CS phone number doesn’t answer and, if the 2
-nd
CS phone number is programmed in section [75], the
control panel will then try to report the events to the 2
-nd
CS phone number. After the control panel takes again the phone line
over, it will wait for 25 seconds again to receive handshake from CS (2
-nd
CS phone number dialing is included). If neither the
2
-nd
CS phone number answer, the panel will make a pause of 32 seconds and then will repeat the procedure up to 8 times for
both phone numbers. So, in case of alternate reporting, if no CS phone number answers, then the calling sequence is the
following:
[25 seconds: 1
-st
CS phone number dialing and waiting for handshake][25 seconds: 2
-nd
CS phone number dialing and
waiting for handshake][pause of 32 seconds][25 seconds: 1
-st
CS phone number dialing and waiting for
handshake][25 seconds: 2
-nd
CS phone number dialing and waiting for handshake][pause of 32 seconds] and so on
up to 8 times for both phone numbers.
Please note if anyone of CS phone numbers isn’t p-programmed, then the dialing of the respective phone number will be skipped.
If even after the 8 attempts for both CS phone numbers no central station answers, then the control panel will record a “CS1 and
CS2 communication failed” event into the 400-event LOG and a specific reporting code into the CS 80-event internal buffer, too.
Upon a new reportable event occurring, if the communication with CS is established, the entire list from CS internal buffer, the old
reporting codes, the new reporting codes and the failed communication
reporting code, which is already in the list, will be reported
together to the CS. In the same time this trouble condition will turn the SYSTEM LED blinking and the zone 3 LED ON, within
system trouble displaying menu - [*][4] command. If this trouble condition occurred for the first time, then the keypad trouble
buzzer warnings will be activated, too, and the keypad will emit intermittent beeps, at every 8 seconds, until the users will
acknowledge the trouble by means of [*][4] command, or until system/partition arming. So, as soon as the users had
acknowledged the troubles by means of [*][4] command, the keypad trouble buzzer warnings will stop, as there are no troubles in
the system, but the SYSTEM LED will still remain blinking (and the zone 3 LED will still remain ON within system trouble displaying
menu) until a successful transmitting to the “central station”.
3. In case the reporting to CS is programmed in this section as split (or double), the panel will report to the central
stations as follows:
If 1
-st
CS phone number is programmed in section [74], the control panel will first try to report to this phone number
any event to be reported to CS1, selected in section [30]. After the control panel takes the phone line over for CS1 transmitting, it
will wait 25 seconds for handshake receiving from CS1 (1
-st
CS phone number dialing is included). In case 1
-st
CS phone number
doesn’t answer, the panel will make a pause of 32 seconds and then will dial the phone number and wait again for 25 seconds to
receive handshake; if again the phone number doesn’t answer, the panel will make again a pause of 32 seconds and the procedure
will be repeated up to 8 times.
Please note that even there in section [30] are events selected to be reported to CS1, if in section [74] the 1
-st
CS phone number
isn’t programmed, the control panel will not initiate reporting to CS1 and will not record events into the CS1 80-event internal
buffer anymore.
If even after the 8 attempts the 1
-st
central station doesn’t answer (the control panel failed to report the events to CS1), then the
control panel will record a “CS1 communication failed” event into the 400-event LOG and a specific reporting code into the CS1 80-
event internal buffer, too. Upon a new reportable event occurring, if the communication with CS1 is established, the entire list
from CS internal buffer, the old reporting codes, the new reporting codes and the failed communication reporting code, which is
already in the list, will be reported together to the CS1. In the same time, if an event of “CS1 communication failed” occurred in
the system, the specific reporting code will be recorded into the CS2 80-event internal buffer and will be transmitted to CS2, too.
This trouble condition will turn the SYSTEM LED blinking and the zone 3 LED ON, within system trouble displaying menu - [*][4]
command. If this trouble condition occurred for the first time, then the keypad trouble buzzer warnings will be activated, too, and
the keypad will emit intermittent beeps, at every 8 seconds, until the users will acknowledge the trouble by means of [*][4]
command, or until system/partition arming. So, as soon as the users had acknowledged the troubles by means of [*][4]
command, the keypad trouble buzzer warnings will stop, as there are no troubles in the system, but the SYSTEM LED will still
remain blinking (and the zone 3 LED will still remain ON within system trouble displaying menu) until a successful transmitting to
both CS1 and CS2.
After a successful or failed reporting to CS1, if 2
-nd
CS phone number is programmed in section [75], then the control panel
will try to report to this phone number any event to be reported to CS2, selected in section [31]. After the control panel takes the