EasyManua.ls Logo

ROEL Cerber C62 - SECTION [49] - FIRST PANEL ACCOUNT FOR IDENTIFYING AT CS; SECTION [50] - SECOND PANEL ACCOUNT FOR IDENTIFYING AT CS2; SECTION [51] - 1-ST REPORTING FORMAT; 2-ND REPORTING FORMAT

ROEL Cerber C62
82 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
63
f. [7] key and blinking of 1 and 6 zone LEDs for 7
-th
voice message recording;
g. [8] key and blinking of 2 and 6 zone LEDs for 8
-th
voice message recording;
In order to exit “voice message recording” menu, press [#] key.
For more details, see instructions on voice module MPV8, too.
SECTION [49] - FIRST PANEL ACCOUNT FOR IDENTIFYING AT CS
Enter 4 digits (HEX digits may be used), which will stand for the first control panel account.
The following sequence will be introduced:
[x][x][x][x] |0||0||0||0| by default
The keypad buzzer will sound 3 beeps after any digit entering and 6 beeps after entering of the last
one. Then the panel exits the section and will wait for a new command to enter another section.
After any digit was pressed, programming of the first panel account may be canceled by [#] key
pressing. After cancellation by [#] key pressing, the keypad buzzer will sound 6 confirmation beeps,
the system will keep the old value for the first panel account and the control panel will go back within
“main programming menu”
To exit the “main programming menu”, press [#] key.
Notes:
1. By default, the first panel account is 0000.
2. Any time when the control panel is dialing the 1
-st
CS phone number, in order to identify itself to CS, the control panel will
use the first panel account which is set in this section, irrespective of way the alternate or split reporting option was set.
SECTION [50] - SECOND PANEL ACCOUNT FOR IDENTIFYING AT CS2
Enter 4 digits (HEX digits may be used), which will stand for second control panel account.
The following sequence will be introduced:
[x][x][x][x] |0||0||0||0| by default
The keypad buzzer will sound 3 beeps after any digit entering and 6 beeps after entering of the last
one. Then the panel exits the section and will wait for a new command to enter another section.
After any digit was pressed, programming of the second panel account may be canceled by [#] key
pressing. After cancellation by [#] key pressing, the keypad buzzer will sound 6 confirmation beeps,
the system will keep the old value for the second panel account and the control panel will go back
within “main programming menu”
To exit the “main programming menu”, press [#] key.
Notes:
1. By default, the second panel account is 0000.
2. In order to identify itself to CS2, the control panel will use the second panel account, which is set in this section, only if the
split (or double) reporting option was set and only while the control panel is dialing the 2
-nd
CS phone number.
SECTION [51] - 1
-ST
REPORTING FORMAT / 2
-ND
REPORTING FORMAT
Enter 2 groups of 2 digits, the first 2-digit group being the type of the format for CS1 transmission and
the second 2-digit group being the type of the format for CS2 transmission.
The following sequence will be introduced:
|__|__||__|__| |10||10| by default (DTMF, 4x2 Ademco Express for both
transmission formats)
The keypad buzzer will sound 3 beeps after the first 2-digit group and 6 beeps after the second one.
Then the panel exits the section and will wait for a new command to enter another section.
To exit the “main programming menu”, press [#] key.
F
ORMAT TYPES FOR DIGITAL TRANSMISSION:
[0][0] 10PPS, 4x2 with parity, 1400Hz kisson, 1800Hz data
[0][1] 10PPS, 4x2 with parity, 2300Hz kisson, 1800Hz data

Table of Contents