EasyManua.ls Logo

ROEL Cerber C62 - SECTION [53] - EVENT REPORTING CODES IN 4 X2 FORMAT REGARDING: STAY ARMING BY USER; STAY KEYSWITCH ARMING; QUICK STAY OR INSTANT STAY ARMING; PARTIAL ARMING; FAIL TO AUTOARM; SECTION [54] EVENT REPORTING CODES IN 4 X2 FORMAT REGARDING: DISARMING BY USER; KEYSWITCH DISARMING; DISARMING FROM PC; TIMED AUTOARMING STOPPING; TIMED AUTODISARMING NOT ALLOWED; SECTION [55] - EVENT REPORTING CODES IN 4 X2 FORMAT REGARDING: ZONE BYPASSED FROM SWINGER; ZONE BYPASSING

ROEL Cerber C62
82 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
65
SECTION [53] - EVENT REPORTING CODES IN 4X2 FORMAT REGARDING: “STAY ARMING BY USER / “STAY
KEYSWITCH ARMING / “QUICK STAY OR INSTANT STAY ARMING / “PARTIAL ARMING / “FAIL TO
AUTOARM
Enter 1 digit for “stay arming by user code” and 4 groups of 2 digits (HEX digits may be used), one
group for each reporting event.
The following sequence will be introduced:
|__||__|__||__|__||__|__||__|__| |C||00||00||00||00| by default
The keypad buzzer will sound 3 beeps after each group and 6 beeps after the last digit. Then the panel
exits the section and will wait for a new command to enter another section.
To exit the “main programming menu”, press [#] key.
Notes:
1. If one event code should keep its value previously set, press [#] key instead of the corresponding group.
2. If one event code isn’t to be reported to CS, the group (digit) which corresponds to the event will be set as [00] value (or as
[0] value).
3. The digit specific for “stay arming by user” event will be used by the panel to generate the event code for transmission to the
“central station” in 4x2 formats (4 account digits + 2 event digits). So, in order to get the 2 event digits, the panel will
automatic add to this specific digit the corresponding digit of the user number (for all users from 15 to 45 the
identifying digit of user number will be eitherF” or modulo 16, according to the corresponding flag programming from section
[29]).
S
ECTION [54] - EVENT REPORTING CODES IN 4X2 FORMAT REGARDING: “DISARMING BY USER /
“KEYSWITCH DISARMING / “DISARMING FROM PC” / “TIMED AUTOARMING STOPPING / “TIMED
AUTODISARMING
NOT ALLOWED
Enter 1 digit for “Disarming by user” code and 4 groups of 2 digits (HEX digits may be used), one
group for each reporting event.
The following sequence will be introduced:
|__||__|__||__|__||__|__||__|__| |B||00||00||00||00| by default
The keypad buzzer will sound 3 beeps after each digit group and 6 beeps after the last digit. Then the
panel exits the section and will wait for a new command to enter another section.
To exit the “main programming menu”, press [#] key.
Notes:
1. Timed autoarming stopped” code will be transmitted to CS by the panel, if during the 3 minutes before timed
autoarming, while the keypad buzzer is warning that the system will auto arm by time, autoarming is stopped by any
valid user code.
2. The time for audible warnings before timed autoarming is fixed at 3 minutes.
3. If one event code should keep its value previously set, press [#] key instead of the corresponding group (digit).
4. If one event code isn’t to be reported to CS, the group (digit) which corresponds to the event will be set as [00] value (or
as [0] value).
5. The digit specific to "Disarming by user” event will be used by the panel to generate the event code for transmission to
the “central station” in 4x2 formats (4 account digits + 2 event digits). So, in order to get the 2 event digits, the
panel will automatic add to this specific digit the corresponding digit of the user number (for all users from 15
to 45 the identifying digit of user number will be either “F” or modulo 16, according to the corresponding flag
programming from section [29]).
SECTION [55] EVENT REPORTING CODES IN 4X2 FORMAT REGARDING: “ZONE BYPASSED FROM SWINGER /
“ZONE BYPASSING
Enter 2 digits (HEX digits may be used), one digit for each event.
The following sequence will be introduced:
|__|__| |0|0| by default
The keypad buzzer will sound 3 beeps after the first digit and 6 beeps after the second one. Then the
panel exits the section and will wait for a new command to enter another section.
To exit the “main programming menu”, press [#] key.
Note:
1. Second reporting code of zone bypassing will be transmitted to CS only upon arming, if there are in the system:
- Bypassed zones by the panel – in case of partial arming and the respective zones are as interior type and/or

Table of Contents