71
3. Any time when the control panel will dial this phone number, in order to identify itself to CS, the control panel will use the
first panel account which was established in section [49] and will transmit in the 1
-st
reporting format which was established
in section [51].
SECTION [75] - PHONE NUMBER OF CS2
Enter the phone number in the same way it would be dialed on a touch-tone phone. The maximum
number of digits is 15.
To confirm the phone number, press [#] key after the last digit of the phone number was entered.
After [#] key pressing, the keypad buzzer will sound 6 confirmation beeps and the panel exits the
section and will wait for a new command to enter another section or [#] key to exit the “main
programming menu”.
A 2-second pause can be added by entering HEX digit D between the digits of the phone number (enter
HEX digit D by pressing [*] and [3] keys).
In order to erase the phone number, press [*] key, once the panel entered this section.
Notes:
1. In case the reporting to CS is programmed in [29] section as alternate, for control panel to initiate CS reporting, at
least one CS phone number must be programmed in [74] or [75] sections. If 1
-st
CS phone number doesn’t answer and if
2-nd CS phone number is programmed in this section, this is the phone number that the control panel will dial
for the second time in order to transmit to the “central station” the events occurred in the system. If 1
-st
CS
phone number isn’t programmed in [74] and if 2-nd CS phone number is programmed in this section, this is the phone
number that the control panel will dial in order to transmit to the “central station” the events occurred in the system. In
order to identify itself to CS the control panel will use the first panel account which was established in section [49] and will
transmit in the 1
-st
reporting format which was established in section [51].
2. If the digital communicator is enabled by programming, then:
- In case the alternate reporting is selected in section [29], in order to transmit to the “central station” the events
occurred in the system, this is the phone number that the control panel will dial for the second time, in case 1
-
st
CS phone number doesn’t answer.
- In case the split (or double) reporting is selected in section [29], then the panel will report to CS2 any event selected
in section [31], after reporting to CS1 finished or failed. In order to identify itself to CS2 the control panel will use the
second panel account which was set in section [50] and will transmit in the 2
-nd
reporting format which was established
in section [51]. Please note that if this phone number isn’t programmed, the control panel will not initiate reporting to
CS2 and will not record events into the CS2 80-event internal buffer anymore, even there in section [31] are events
selected to be reported to CS2.
3. Phones numbers in sections [74] and [75] are not programmed by default.
SECTION [76] – HOUR / MINUTE FOR THE FIRST PERIODICAL TEST
Enter 2 groups of 2 digits, the first 2 digits for the hour (00 to 23) and the second 2 digits for the
minute (00 to 59) when the system will send the first periodical test.
The following sequence will be introduced:
|__|__||__|__| by default first periodical test is sent at 19
00
The keypad buzzer will sound 3 beeps after the first 2-digit group and 6 beeps after the second one.
Then the panel exits the section and will wait for a new command to enter another section.
To exit the “main programming menu”, press [#] key.
S
ECTION [77] – TIME BETWEEN THE PERIODICAL TESTS (IN HOURS OR MINUTES)
Enter 1 group of 3 digits for time between the periodical tests (001 to 255 hours or minutes).
The following sequence will be introduced:
|__|__|__| By default 24 hours
The keypad buzzer will sound 6 confirmation beeps after the 3-digit group and the panel exits the
section, waiting for a new command to enter another section.
Press [#] key instead of the 3-digit group if you want to cancel programming of this time interval.
To exit the “main programming menu”, press [#] key.
Note: For this time interval any value from 000 to 999 may be entered, but the panel will automatic adjust the introduced
value by modulo 256 and will record the result in memory as programmed value. If the result of adjustment is 0, then the
periodical tests will be transmitted after every minute or hour!