8
Description of LEDs’ meaning according to the system status:
READY LED
a) While the system is totally armed – OFF.
b) While the system is partially armed:
ON – the system is ready for arming (all zone loops are closed even those which allow
“forced arming” feature);
Blinking the system is ready for being armed (all zone loops are closed but not those
which allow “forced arming” feature);
OFF – at least one zone is open (only those without attribute “forced arm” activated);
c) While the system is partially armed and finds itself within one of the Programming Menus:
ON while the master user is programming/modifying the user codes, the follow me
phone numbers or the system time and date;
ON – while the installer is being within one of the system parameter programming
sections.
d) While the system is being armed, during the exit delay:
ON - if all zone loops stay closed even those which allow “forced arming” feature;
Blinking if all zone loops stay closed but not those which allow “forced arming
feature.
SYSTEM LED
A) While the system is:
armed in regular modeOFF;
armed in home mode
Blinking in case there are recorded alarms during that home arming period and/or there
are troubles in the system (“AC power loss”, “low voltage on battery”, “fail to communicate
event”, “BELL trouble”, “phone line trouble” or “system time and date loss”);
ON in case there is in the system at least one zone bypassed by user and/or if there is at
least one interior zone bypassed by the system
Alternating, 3 seconds ON, 3 seconds blinking in case both conditions are met: in the
same time there are troubles and/or recorded alarms and zones bypassed, too, in the system.
During any exit delay timeBlinking in case there are troubles in the system.
b) While the system is partially armed:
Blinking – in case there are recorded alarms (during the previous arming period or during
that Disarming period for 24h zones) or there are troubles in the system (“AC power loss”,
“low voltage on battery”, “fail to communicate event”, “BELL trouble”, “phone line trouble” or
“system time and date loss”);
ON – in case there is in the system at least one zone bypassed by user;
Alternating, 3 seconds ON, 3 seconds blinking in case both conditions are met: in the
same time there is in the system at least one zone bypassed by user and there are in the
system troubles and/or recorded alarms since last arming;
Blinkingwhen the user is being within one of the next menus: Zone bypassing, System
trouble displaying, Alarm memory displaying or Program/Modify of the: user codes, follow me
phone numbers or system time and date;
Blinking – while the installer is being within programming menu of the system parameters.
ARMED A LED
a) While the partition A or the system is armed:
ON – if the partition A or the system is totally armed;
Fast Blinking – if the partition A or the system is armed in “instant stay mode”.