17
EN
17
5 Typical installation
3x1.5/230 V
3x0.5-TX
5x0.5-RX
RG58
2x1
5x0.5-RX
3x0.5-TX
3x0.5
DESCRIPTION RECOMMENDED CABLE
1 BH30 Automation Power supply H07RN-F 3x1,5 mm2 double insulated cable
2
External photocell F4ES/F4S - Transmitter
Power supply 24Vac 50Hz, 24Vdc
Cable 3x0,5 mm
2
(max 20 m)
External photocell F4ES/F4S - Receiver Cable 5x0,5 mm
2
(max 20 m)
3
Internal photocell F4ES/F4S - Transmitter
Power supply 24Vac 50Hz, 24Vdc
Cable 3x0,5 mm
2
(max 20 m)
Internal photocell F4ES/F4S - Receiver Cable 5x0,5 mm
2
(max 20 m)
4
Flashing light
Power supply 24Vdc a LED
(25 W max, power consumption 50%)
Cable 2x1 mm
2
(max 10 m)
Antenna Cable 50 Ohm RG58 (max 10 m)
5
Key selector R85/60 Cable 3x0,5 mm
2
(max 20 m)
Keypad H85/TTD - H85/TDS
board DECODER
H85/DEC: Power supply 12-24Vdc
H85/DEC/2: Power supply 24Vdc
Cable 2x0,5 mm
2
(max 30 m)
6 Rack /
7 Limit switch bracket /
6 Dimensions
165,8
83
315
329