MC16 Operating Manual 09.01.2020
Incoming Auto-arming Status
Triggered as long as warning before Alarm Zone auto-arming is signaled.
Incoming Auto-arming Signaling Time and other auto-arming parameters are
configured within Alarm Zone.
Access Denied at Access Point
Triggered when access denying results from use of input function [151],
[152], [175] or [176].
Triggered when user is randomly selected for personal check after
identification at Access Point. The probability is specified by function
parameter Intensity [%]. Additionally the user can be denied access if Access
Point option Deny access on random personal check is enabled.
Triggered when Intruder Alarm is finished.
Triggered when Intruder Alarm is raised or finished.
Triggered as long as entry delay is signaled within Alarm Zone.
Triggered when entry delay is started within Alarm Zone.
Triggered when entry delay is finished within Alarm Zone.
Triggered when entry delay is started or finished within Alarm Zone.
Triggered as long as Alarm Zone is ready to arm.
Triggered when Alarm Zone is ready to arm.
Triggered when Alarm Zone is no longer ready to arm.
Triggered when Alarm Zone is ready to arm or is no longer ready to arm.
Triggered when warning before Alarm Zone auto-arming is started. Incoming
Auto-arming Signaling Time and other auto-arming parameters are
configured within Alarm Zone.
VDR Power Output Overload
Status
Triggered as long as VDR power output is overloaded.
VDR Power Output Overload ON
Triggered when VDR power output is overloaded.
VDR Power Output Overload OFF
Triggered when VDR power output is no longer overloaded.
TML Power Output Overload
Status
Triggered as long as TML power output is overloaded.
TML Power Output Overload ON
Triggered when TML power output is overloaded.