EasyManua.ls Logo

Roger MC16 - Page 37

Roger MC16
52 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
MC16 Operating Manual 09.01.2020
37/52
Access Point.
87
Incoming Auto-arming Status
Status
Alarm Zone
Triggered as long as warning before Alarm Zone auto-arming is signaled.
Incoming Auto-arming Signaling Time and other auto-arming parameters are
configured within Alarm Zone.
88
Access Denied at Access Point
Event
Access Point
Triggered when access denying results from use of input function [151],
[152], [175] or [176].
89
Random Personal Check
Event
Access Point
Triggered when user is randomly selected for personal check after
identification at Access Point. The probability is specified by function
parameter Intensity [%]. Additionally the user can be denied access if Access
Point option Deny access on random personal check is enabled.
90
Intruder Alarm OFF
Event
Alarm Zone
Triggered when Intruder Alarm is finished.
91
Intruder Alarm ON/OFF
Event
Alarm Zone
Triggered when Intruder Alarm is raised or finished.
92
Entry Delay Status
Status
Alarm Zone
Triggered as long as entry delay is signaled within Alarm Zone.
93
Entry Delay ON
Event
Alarm Zone
Triggered when entry delay is started within Alarm Zone.
94
Entry Delay OFF
Event
Alarm Zone
Triggered when entry delay is finished within Alarm Zone.
95
Entry Delay ON/OFF
Event
Alarm Zone
Triggered when entry delay is started or finished within Alarm Zone.
96
Ready to Arm Flag Status
Status
Alarm Zone
Triggered as long as Alarm Zone is ready to arm.
97
Ready to Arm Flag ON
Event
Alarm Zone
Triggered when Alarm Zone is ready to arm.
98
Ready to Arm Flag OFF
Event
Alarm Zone
Triggered when Alarm Zone is no longer ready to arm.
99
Ready to Arm Flag ON/OFF
Event
Alarm Zone
Triggered when Alarm Zone is ready to arm or is no longer ready to arm.
100
Incoming Auto-arming ON
Event
Alarm Zone
Triggered when warning before Alarm Zone auto-arming is started. Incoming
Auto-arming Signaling Time and other auto-arming parameters are
configured within Alarm Zone.
139
VDR Power Output Overload
Status
Status
Power Supply
Triggered as long as VDR power output is overloaded.
140
VDR Power Output Overload ON
Event
Power Supply
Triggered when VDR power output is overloaded.
141
VDR Power Output Overload OFF
Event
Power Supply
Triggered when VDR power output is no longer overloaded.
142
TML Power Output Overload
Status
Status
Power Supply
Triggered as long as TML power output is overloaded.
143
TML Power Output Overload ON
Event
Power Supply
Triggered when TML power output is overloaded.