V L F > H F R E C E I V E R S
f
E K 8 9 5 / E K 8 9 6
Operator Manual
f
Special Functions
2.4 Special Functions
The following special functions are possible:
f Inhibiting or enabling the level line
1)
f Inquiry of level line status
1)
f Initiation of BIT and/or inquiry of BIT status
1)
f Inquiry of CM status
1)
f Inquiry of receive level
1)
f Storage into a channel
1)
f Channel call>up
f Editing the channel contents
1)
f Switching the digital selection on or off (with FK 896 only)
1)
f Switching the preamplifier on or off
1)
These commands are described in the User Manual 6045.6712.12.xx.
2.4.1 Channel Call>up
Command syntax:
Code: K
Parameter: .................... a,b
z: ................................... s (set)
Possible entry
Range: .......................... 0 to 999
Note:
Inhibited channels (K<parameter>,e; see
A3.7.11 in the User Manual 6045.6712.12.xx)
are automatically reactivated upon command
Ks,<parameter>, that is, the flag 'e' is can>
celled.
Only those channels are permitted to be called
up where one of the following modulation
modes is stored:
LL LU LIL LIU
Example:
Calling up channel 873
Command = rAxxKs,873?
Æ Operating mode CHANNEL
2.4.2 Inquiry of Channel Contents
Command syntax:
Code: K
Parameter: .................... a
Possible entries
Range: .......................... 0 to 999
Example:
Inquiry of current receiver setting
Command= rAxxK??
Æ Reply = rAxxK
≤≥
F801000I15?
Note:
The blank '
≤≥
'
following the letter K means,
that there is no channel set.
The following settings are effective at the mo>
ment:
f Operating mode: K
≤≥ =
MANUAL
f Frequency: F801000 = 801 kHz
f Modulation mode: I15 = L USB
6075.6991.82.01
> 2.5 >