Remote control commands
R&S
®
RTM3000
594User Manual 1335.9090.02 ─ 09
Setting parameters: 
<MessageText> String
String that contains the message.
Example: 
DISP:DIAL:MESS 'My message'
DISP:DIAL:CLOS
Usage:  Setting only
DISPlay:GRID:STYLe <Style>
Defines how the grid is displayed.
Parameters:
<Style> LINes | RETicle | NONE
LINes
Displays the grid as horizontal and vertical lines.
RETicle
Displays crosshairs instead of a grid.
NONE
No grid is displayed.
*RST:  LIN
DISPlay:INTensity:GRID <Intensity>
Defines the brightness of the grid lines in the diagram.
Parameters:
<Intensity> Range:  0  to  100
Increment:  1
*RST:  not available, *RST does not change the intensity
Default unit: %
DISPlay:INTensity:WAVeform <Intensity>
Defines the brightness of the waveform lines in the diagram.
Parameters:
<Intensity> Range:  0  to  100
Increment:  1
*RST:  not available, *RST does not change the intensity
Default unit: %
DISPlay:PALette <Palette>
Sets the color and brightness of the displayed waveform samples depending on their
cumulative occurance.
Parameters:
<Palette> NORMal | INVerse