EasyManua.ls Logo

Rohde & Schwarz Scope Rider RTH - Page 172

Rohde & Schwarz Scope Rider RTH
530 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Protocol Analysis
R&S
®
Scope Rider RTH
172User Manual 1326.1578.02 ─ 12
Figure 9-1: Bus menu. Left: for protocols without address (SPI, UART). Right: for protocols with
address or identifier (I²C, CAN, LIN, SENT)
For all serial protocols, the following settings are required:
State
Enables the decoding and the display of the serial bus data.
Remote command:
BUS[:STATe] on page 426
Bus Protocol
Defines protocol type of the bus for configuration and trigger settings.
Remote command:
BUS:TYPE on page 426
Display Format
Sets the decoding format of data values: binary, hexadecimal, decimal, octal, or ASCII.
The format is used in comb display and in the protocol table. Address values are
always hex values.
Remote command:
BUS:FORMat on page 426
Basics of Protocol Analysis

Table of Contents

Other manuals for Rohde & Schwarz Scope Rider RTH

Related product manuals