065 75$16&(,9(5 ; $ ; $
Operator’s Manual Use under Special Conditions
– 3.60 – 6076.0822.12.01
0HQX648(/&+32/$5,7<
In this menu the polarity of the squelch signal output level is displayed and edited.
Starting point: Menu 400, page 2 (RADIO MAINTENANCE)
+ Press softkey (10) and the following display appears:
No. Control Action Notes
2 Press softkey
ACTIVE.
The active polarity is switched from low to
high and vice versa:
9 Press softkey
SAVE.
Saves the current configuration.
The asterisk (*) indicates that the new
settings have not yet been stored.
softkey SQUELCH... POLARITY
Active level:
High - positive polarity
Low - level 0 V
+ Select squelch