Summary

General Information

Quick Instructions

Starting the Programme

Steps to power on the controller and begin a firing process.

Changing the Programme

How to modify firing curve values before or during a process.

Operating Elements

Calling Up a Programme

Initiating the Firing Process

Steps to start the selected firing programme after calling it up.

Display During Firing Process

Input and Control of Firing Curve

The SKIP Value

Setting the SKIP value to reach final temperature quickly during the second heating phase.

Storing Programmes

Display of Kiln Temperature

Process Monitoring Displays

Control Outlet and Event Status

Shows control outlet status and information on special process events.

Operational Time and Power Data

Displays power consumption and heating element operating time.

Locking the Controller

Power Failure Handling

Actual Duration of a Ramp

Kiln Cannot Follow Ramp

Forward Switching for SKIP Ramps

Programme Abortion at Failure

Stop Firing Process

Appendix A: Event Display

Measurement and Safety Events (A1, A3)

Events related to measurement input errors and safety circuit activation.

Kiln Performance and Control Events (A4, A5, A8, A9)

Events indicating kiln issues with temperature increase, control, or ramp switching.

Power Failure and System Events (B2, B3)

Events related to firing continuation or abortion after power failures.

Internal and Hardware Faults (C1-C4, D1-D5)

Events indicating internal controller problems or hardware failures requiring support.

Appendix B: Data and Events Memory

Data Memory Overview

Records important values like temperature and timing for the last 36 hours.

Event Memory Overview

Records special events like programme interruptions or power failures, up to 50 events.

Calling Up Stored Data

Calling Up Stored Events

Appendix C: Configuration

Parameter Overview and Safety

Presents parameters and provides warnings on settings and safety.

Parameter Explanations (1-9)

Detailed explanation of parameters like kiln performance, thermocouple type, and heating control.

Parameter Explanations (10-20)

Explains zone configuration, ramp input, and control outlet functions.

Calling Up Configuration

Extensive Parameter List

Appendix D: Data Interface

Appendix E: Calling Up Layout

Appendix F: Electrical Connection

Plug Designation and Connections

Details plug designations (HAN7D, HAN15D, CPC14) and their pinout connections.

Important Notes on Thermocouple Type

Advice to compare thermocouple type with controller specification to prevent damage.

Rohde TC 504 Specifications

General IconGeneral
CategoryController
TypeTemperature Controller
Control AlgorithmPID
Protection RatingIP20
InputsThermocouple (Type K, J, T, N, S)
OutputsAnalog (0/4-20mA or 0-10V)
DisplayLED
Power Supply24 V AC/DC
Operating Temperature0 to 50 °C

Related product manuals