Feb.2005
44
Move the Bender lever completely to the left and press the SET LIST SW button, the
display will show:
Move the Bender lever completely to the right and press the SET LIST SW button, the
display will show:
Release the Bender lever at the center and press the SET LIST SW button, the display will
show:
Push the Bender lever completely to the center and press the SET LIST SW button. To
confirm the calibration, the instrument exits the test, resets itself and reverts to the video of
the main menu.
8 - SAVE SYSTEM ON CARD (INTERNAL USE ONLY)
** BENDER CALIBRATION **
Calibrating the HARD RHIGT POSITION :
Move Pitch Bend lever, to the Right and press LIST SW
** MODUL CALIBRATION **
Release the Modulation Lever :
Press the LIST SW
** MODUL CALIBRATION **
Press the Modulation Lever To the back of the G-70
and press LIST SW