XP-60Apr. 1998
23
6. SW & LED TEST.
NOTE : When the amp is connected to the OUTPUT jack,
piano sound when a button is pressed.
Scale sounds in sequence when the panel switches
are pressed in order.
Fig.10
Display shows [Fig.10].
Do all LED light on ? (44 units)
Check: IC 1,2,4 Q1-16 on SBB,
Ribon Cable(11P)(12P) SBB-MB
Press buttons. Check going off its LED or name on LCD.
Only SW 23(STOP/PLAY) must be pressed twice,
because LED 45(BEAT) is 2 colored (red,green) LED.
Check: LED SW D on SB
SW & LED test is complete.
When the test was successful, move to next test item.
7. LCD TEST.
Fig.11
Display shows [Fig.11].
LED (TRAC/PART, 4) light on.
Press ENTER. All dots turn on green.
Press ENTER. All dots turn on dark.
Check: IC18,19 on MB
Turn encoder right and left, does LCD change
contrast bright and dark ?
And the LED moves on both side ?
Check: IC13 on MB
Ribon Cable(3P) ENB-MB
LCD test is complete.
YES
YES
YES
NO
NO
NO
NO
NO
YES
6. SW & LEDテスト
注: OUTPUT ジャックにアンプを接続しておけば、
ボタンを押したとき音がでます。
パネル上のスイッチを順番に押すと、音階順に
発音します。
LCDはFig.10のように表示されます。
全LED(44個)が点灯するか?
Check: IC 1,2,4 Q1-16 on SBB,
Ribon Cable(11P)(12P) SBB-MB
ボタンを1つずつ押す。押されたボタン
のLEDかLCD上の表示が消えるか?
LED45(BEAT)は2色 LEDを使用している
のでSW23(STOP/PLAY)は2回押して下さい。
Check: LED SW D on SB
SW & LEDテスト終了。
このテストがOKの場合次の項目へ自動的に移動します。
7. LCDテスト
LCDはFig.11のように表示されます。
TRAC/PART, 4 のLEDが点灯します。
ENTER を押す。LCD一面が緑色になる。
ENTER を押す。LCD一面が濃くなる。
Check: IC18,19 on MB
エンコーダーを左右に回すと、LCDのコ
ントラストが変化するか?
LEDの灯りが左右へ動くか?
Check: IC13 on MB
Ribon Cable(3P) ENB-MB
LCDテスト終了
YES
YES
YES
NO
NO
NO
NO
NO
YES