Important features
Microprocessor technology
LC display (green), 4 lines, 20 characters, (multilingual)
Alternatively:
VF display (blue), 4 lines, 20 characters, (multilingual)
Automatic zero calibration (AUTOCAL)
Automatic optimization (AUTOTUNE)
Automatic configuration of the secondary voltage and current ranges
(AUTORANGE, as of software revision 100)
Automatic phase angle compensation (AUTOCOMP, as of software revision 100)
Automatic frequency adjustment
Large current and voltage range
Booster connection as standard
Heatsealing band alloy and temperature range selectable
Time control, heatsealing time and cooling time settable
Preheating
Configurable relay output, e.g. "end of cycle"
Time or temperature-controlled cooling phase
Signal output for "Temperature OK"
0…10VDC analog output for ACTUAL temperature
Alarm function with fault diagnosis
Identical design to and compatible with RES-222, -230, -241, -242
Operating
Instructions

Table of Contents

Other manuals for Ropex RESISTRON RES-440

Question and Answer IconNeed help?

Do you have a question about the Ropex RESISTRON RES-440 and is the answer not in the manual?

Ropex RESISTRON RES-440 Specifications

General IconGeneral
Control algorithmPID
DisplayLED
Protection classIP20
Weight300 g
Input typeThermocouple, Pt100
Output typeRelay, SSR
Ambient temperature range0°C to 50°C
Dimensions96 x 48 x 112 mm

Summary

General Information

Principle of Operation

Description of the Controller

Technical Data

Installation

Installation Procedure

Step-by-step guide for installing the RESISTRON temperature controller RES-440.

Startup and Operation

Controller Configuration

Explains various configuration options, including DIP switches, language, and settings.

Controller Functions

Error Messages

Details how the controller signals faults, displays error codes, and prompts for reset.

Automatic Zero Calibration (AUTOCAL)

Describes the automatic process to match the controller to system signals for accurate calibration.

Time Control (Timer Function)

Details the activation and operation of the timer function for automated heatsealing processes.

Fault Areas and Causes

Provides a detailed breakdown of potential faults, their causes, and troubleshooting actions.

Factory Settings