Step 4: Installing Locking Latch Assemblies And Position
Sensors To Latch Plates On Posts:
Note: All components can be mounted to the posts before
lowering them into the front and rear housings.
A.) Install latch assemblies and post position sensors onto latch
plates of posts with 3/4"-10NC hex nuts, bolts and lock washers,
Fig. 4.
Step 5: Installing Lock Assembly Into Locking Latch Assembly:
A.)
IMPORTANT
The stop blocks must be removed before lock
assemblies can be lowered into position, Fig. 5.
B.) Install air line guard to lock assembly, Fig. 5.
C.) Pull locks back on locking leg assemblies and lower lock
assemblies into locking leg assemblies, Fig 5a.
D.) Reinstall the stop blocks after the lock assemblies have been
lowered into position.
Fig. 4
Attach Locking Latch Assembly
To Locking Latch Plate On Post
Locking Latch Plate
(4) 3/4" Helical Spring Lock Washer
Jack Position Sensor
And Post Position
Sensor Adapter
(4) 3/4"-10NC Hex Nut Torque to 100 ft. lbs.
Post
String
Note: Pay attention to the orientation of the post position sensor
mounting. The string protruding out of the top of the sensor goes
next to the post.

Other manuals for Rotary 100 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rotary 100 Series and is the answer not in the manual?

Rotary 100 Series Specifications

General IconGeneral
BrandRotary
Model100 Series
CategoryLifting Systems
LanguageEnglish

Related product manuals