3
1. Lift Location: Use architects plan when
available to locate lift. Fig. 1a & Fig. 1b shows
dimensions of a typical bay layout.
2. Lift Height: See Fig. 4 for overall lift height of
each specific lift model. Add 1 min. to overall
height to lowest obstruction.
WARNING
DO NOT install this lift in a pit
or depression due to fire or explosion risks.
3. Column Extensions: Before standing columns
upright, install the column extensions using (12)
3/8-16NC x 1/2 Flanged HHCS, Fig. 4.
4. Latch Cable Guides: Install the latch cable
guides to column extensions with (4) 1/4-20NC x
1 HHCS and 1/4-20NC Flanged Locknuts, Fig. 1c,
Fig. 1d, & Fig. 10b.
NOTE: Latch cable guide must be toward approach
side of the column extension. Coat the cable contact
surface with a light grease such as TUFOIL.
Run nut down just
below impact section
of bolt. Drive anchor
into hole until nut and
washer contact base.
Clean hole.
Drill holes using
3/4" carbide
tipped masonary
drill bit per ANSI
standard
B94.12.1977
4-1/4"
Tighten nut with
Torque wrench to
150 ft.-lbs.
2-1/4"
3-1/4"
4-1/4"
Installation torque of 150 ft-lbs. is required for all anchor bolts.
NOTE: If more than 2 horse shoe shims are used at any of the column
anchor bolts, pack non-shrink grout under the unsupported area of the
column base. Insure shims are held tightly between the baseplate and
floor after torquing anchors.
IMPORTANT: All star washers are to be mounted on the right
side column to ensure grounding of overhead limit switch. Star
washers are not needed when mounting to left side column.
Notice the column extension mounting, Fig. 4 and overhead limit
switch mounting as well in Fig. 6.
Fig. 2
Fig. 3
Shims
(1/2" Max.)
Nut
Flat
Washer
Anchor
NOTE: Use
rectangular shims at
inside edge of
baseplate. Use
constructions
adhesive or silicon
cement to hold shim
in place. INSURE
shims are held tightly
between base plate
and floor after
torquing anchors.
3/8"-16NCx1" HHCS
& Flanged Locknut
(2)3/8" Star Lockwashers
on right side only
Use (1) 3/8" Star
Lockwasher on right extension
Use (4) 3/8"-16NCx1/2"
Flanged HHCS in front
and (2) in the back
12' 0" (3658mm)
Top of Cylinder
11' 8" (3556mm)
Top of Overhead
Assembly(std.)
11' 4" (3454mm)
Top of Overhead
Assembly
(Low Ceiling)
All above for
both SPOA7
and SPOA9
(Low Ceiling is
N/A for SPO9)
Overhead Assembly
Fig. 4
APPROACH
1/4"-20NC x 1"
HHCS & 1/4"
Flanged Locknut
Column
Extension
Latch Cable
Guide
APPROACH
1/4"-20NC x 1"
HHCS & 1/4"
Flanged Locknut
Column
Extension
Latch Cable
Guide
SPO9
SPOA7/SPOA9
Fig. 1c
Fig. 1d

Other manuals for Rotary SPOA9