d06525.fm
20 December 2017 12-10-00
page 8 of 13
Copyright - BRP-Rotax GmbH & CO KG. All rights reserved.
SI-912 i-001R5 / SI-915 i-001
SI-912-016R10 / SI-914-019R10
SERVICE INSTRUCTION
m
WARNUNG
NOTICE
Regarding the temporary use of “100% pure ethylene glycol”. It should be
only a temporary measure. Using the concentrate over time would cause
the additives to drop out and possibly block cooling system passageways.
If true 100% pure ethylene glycol were used, it would be corrosive as it
would not contain any additives.
m
WARNUNG
NOTICE
The above warnings are taken from the manufacturer’s users manual,
however the original text and description in the users manual is binding
(see: www.evanscoolant.com).

Other manuals for Rotax 914 series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rotax 914 series and is the answer not in the manual?

Rotax 914 series Specifications

General IconGeneral
Bore79.5 mm
Stroke61 mm
Compression Ratio9.0:1
Cooling SystemLiquid-cooled cylinder heads, air-cooled cylinders
Redline5800 rpm
Engine Type4-cylinder, 4-stroke
Fuel TypeAvgas 100LL
Oil SystemDry sump
Fuel Systemfuel injection
TBO (Time Between Overhauls)2000 hours
Displacement1.211 liters (1211 cc)
Power Output84.6 kW (115 hp) at 5, 800 rpm

Related product manuals