5 x Service and maintenance
25
BA ROTEX A1 BO - 10/2007
5 Service and maintenance
5.1 General overview of service and maintenance
Regular service and maintenance of the heating system keeps energy consumption down, guarantees a long working life and fault-
free operation of the heating system.
Tests during the annual service:
– General condition of the heating system, visual inspection of connections and pipes.
– Flue gas temperature and flue gas temperature sensor.
– Functioning of the condensate treatment unit (determination of pH value).
– Burner operation and burner settings.
Maintenance work to be carried out annually:
– Cleaning the burner components, the combustion chamber and the heating surfaces.
– Cleaning the boiler panelling and the sound insulation hood.
– Cleaning and regeneration of the Condensate treatment unit.
– Replacement of the consumables (if required).
ROTEX recommends a service and maintenance contract to ensure regular service and maintenance.
• Service and maintenance should be recorded in the maintenance record. The maintenance record is included in the scope of
supply.
WARNING!
Improper service and maintenance work can be a health risk to persons and can adversely affect operation of
the oil condensing boiler.
• Service and maintenance work only by authorised and trained heating experts.
The service and maintenance work should be carried out by authorised and trained heating experts once a year,
if possible before the heating period. This will avoid malfunctions during the heating period.