5 x Inspection and maintenance
27
BA ROTEX GSU - 09/2007
5 Inspection and maintenance
5.1 General overview of inspection and maintenance
Regular inspection and maintenance of the heating system reduces energy consumption and ensures a long life and smooth
operation.
Tests during the annual inspection:
General condition of the heating system, visual inspection of connections and conduits.
Condensate drain, flue gas temperature and possibly optional flue gas temperature sensor.
Burner operation and burner settings.
Maintenance work to be carried out annually:
Cleaning of the burner components, the combustion chamber and the heating surfaces.
Cleaning of the storage tank and the silencer hood.
Replacement of the wearing parts (if required).
ROTEX recommends that you make an inspection and maintenance contract to ensure regular inspection and maintenance.
Have the inspection and maintenance confirmed in the maintenance log. The maintenance log is included in the scope of
delivery.
5.2 Inspection and maintenance tasks
WARNING!
Improperly executed inspection and maintenance jobs can put human life and health in danger and impair the
functioning of the gas condensing boiler.
Work, especially on gas and flue gas-conducting components as well as on electrical systems may only
be carried out by heating engineers who have been authorised and trained by the gas or energy
supply company.
Have the inspection and maintenance carried out by authorised and trained heating engineers once a year and, if
possible, before the heating period. This will avoid malfunctions during the heating period.
WARNING!
Live parts can cause electric shock on contact, and cause life-threatening burns and injuries.
Before beginning maintenance work, disconnect the ROTEX GSU from the power supply ROTEX GSU
(switch off fuse, main switch) and secure against unintentional restart.
WARNING!
Danger of burning on hot surfaces.
Let the burner cool down for an adequate period before maintenance and inspection work.
Wear protective gloves.

Related product manuals