1 x Safety
6
BA ROTEX GSU - 09/2007
Hydraulic system connection
When operating the ROTEX GasSolarUnit, especially when using the solar energy, the storage tank temperature can exceed
60 °C. Protection from scalding (hot water mixing device e.g. VTA32 15 60 16) should therefore be included when
installing the system.
Device installation room
Operate ROTEX GasSolarUnit only if sufficient combustion air supply is ensured. If you operate the ROTEX GSU in ambient-
air-independent mode with an air/ flue gas system (LAS) dimensioned according to ROTEX standard, this is guaranteed
automatically and there are no further conditions to be met in the device installation room.
Make sure that there is an opening to the open air for air inlet, of at least 150 cm
2
if you operate in the ambient air dependent
mode.
Do not operate the burner in the ambient air dependent mode in rooms with aggressive vapours (e.g. hair spray, perchloroeth-
ylene, carbon tetrachloride), heavy dust formation (e.g. workshops) or high humidity (e.g. laundries).
Always maintain the minimum distances from walls and other objects (see Chapter 7.1).
Operation
Operate ROTEX GasSolarUnit only with the storage tank filled to overflow.
Operate ROTEX GasSolarUnit only with closed silencer hoods.
Instruction by the installer
The handover includes instruction in the operation and control of the ROTEX GasSolarUnit by the installer, using the operating
instructions.
Document the handover by filling in and signing the attached installation and instructions form together with the installer.
Disposal
Through the environmentally-friendly design of the ROTEX GasSolarUnit, ROTEX has complied with the standards for
environmentally-friendly disposal.
Proper disposal in compliance with the respective national stipulations of the country of use is the responsibility of the owner.
Documentation
The technical documentation contained in the scope of supply is part of the device. It must be stored in such a way as to
ensure that the operator or technical personnel can always refer to it.