Questions and Answers

  • B
    Bianca SchmidtAug 9, 2025
    How to improve the ultimate vacuum on my Rothenberger Water Pump?
    • K
      kim41Aug 9, 2025
      To address poor ultimate vacuum in your Rothenberger Water Pump, first, ensure the pump has been running long enough, as the final vacuum level depends on the duration of operation relative to the volume being evacuated. Next, check for any leaks in the connections or the system; switch off the pump to see if the vacuum level holds. Also, verify that all connections and equipment used are appropriate. If issues persist, further assistance may be needed.
  • J
    Julia Young DVMAug 14, 2025
    What to do if the vacuum gauge doesn’t move on my Rothenberger ROAIRVAC 1.5?
    • E
      Erica HudsonAug 14, 2025
      If the vacuum gauge on your Rothenberger Water Pump isn't moving while the engine is running, first, verify that the pump is actually sucking in air. If it is, the vacuum gauge itself might be damaged. However, if the pump isn't sucking in air, the non-return solenoid valve could be blocked. If the problem persists, further assistance may be needed.
  • S
    Scott CarsonAug 19, 2025
    Why is my Rothenberger ROAIRVAC 1.5 experiencing oil overconsumption?
    • M
      Mary McintyreAug 19, 2025
      If your Rothenberger Water Pump is experiencing oil overconsumption, first ensure you are using ROTHENBERGER oil. Next, check that the drainage plug is tightly closed to prevent oil spillage. Also, inspect the connections and the system for any leaks, as open systems can increase oil consumption. If the problem persists, further assistance may be needed.
  • K
    Kristen WhiteAug 25, 2025
    What to do if my Rothenberger Water Pump is overheating?
    • C
      Christina WardAug 26, 2025
      If your Rothenberger Water Pump is overheating, start by checking that it's adequately filled with oil. Next, ensure the pump isn't covered and has sufficient airflow around it. Also, verify that the power supply matches the pump's requirements as indicated on its label. If the issue continues, further assistance may be needed.
  • K
    Kathleen MuellerAug 29, 2025
    How to troubleshoot a Rothenberger ROAIRVAC 1.5 Water Pump that doesn’t work?
    • Z
      zwatsonAug 29, 2025
      If your Rothenberger Water Pump isn't working, begin by ensuring it's properly connected to the power supply. Then, inspect the plug and cable for any signs of damage. Next, check that the power supply is suitable for the pump's requirements by referring to the pump's label. Also, verify that the pump is filled with oil. If problems persist, further assistance may be needed.
  • T
    Timothy Harrington DVMSep 3, 2025
    Why is my Rothenberger Water Pump so loud?
    • S
      stacy00Sep 3, 2025
      If your Rothenberger Water Pump has a persistent loud noise, start by checking the fan cover for any damage, as impacts can affect the fan's movement. Next, ensure that the pump is securely screwed in place. If the noise persists, further assistance may be needed.

Rothenberger ROAIRVAC 1.5 Specifications

General IconGeneral
Dimensions280 x 124 x 229 mm
Weight7.7 kg
Pumping speed42 l/min
Power190 W
Voltage220-240 V
Frequency50 Hz
Oil capacity0.25 L
Power Supply230 V, 50 Hz
Power Consumption190 W
Max. Air Flow42 l/min
Tank Capacity0.25 l