EasyManua.ls Logo

Rothenberger RP50-S User Manual

Rothenberger RP50-S
5 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
2 IDIOMA
RP50-S / RP50-S INOX
Bedienungsanleitung
Instructions for use
Instruction d'utilisation
Instrucciones de uso
Istruzioni d'uso
Gebruiksaanwijzing
Instruções de serviço
Bruksanvisning
Användningsinstruktioner
www.rothenberger.com/manuals
6.0200
6.0203
Question and Answer IconNeed help?

Do you have a question about the Rothenberger RP50-S and is the answer not in the manual?

Rothenberger RP50-S Specifications

Capacity IconCapacity
tank volume12 l
piston volume45 ml
Operating Conditions IconOperating Conditions
maximum temperature50º C - 120ºF
maximum pressure60 bar. 860 psi. 6 Mpa
Connections IconConnections
outlet connectionR 1/2”
testing fluidWater, oil
Weight and Dimensions IconWeight and Dimensions
dimensions720x170x260 mm
weight8 kg

Summary

General Safety

Operating Instructions

Connect Hose and Open Valve

Connect pressure hose to equipment with V1 open and V2 closed for initial setup.

Purge Air and Fill Installation

Open purge points, remove handle lock, pump until air is purged, then close vents and fill.

Reach Test Pressure

Continue pumping until the desired test pressure is achieved.

Close Shut-off Valve

Close valve V1 once the test pressure has been reached.

Adjust Pressure if Exceeded

If pressure exceeds limit, open valve V2 slightly to reduce pressure.

Complete Test and Release

If no leaks, open both V1 and V2 valves to complete the test.

Maintenance

Clean Pump System

Keep the tank and pump system clean; clean filter if clogged.

Grease Piston

Periodically grease the piston with water repellent grease carefully.