EP Series User Manual
14
The user can set the upper three bits of the IP address, subnet mask, gateway and
other parameters through the "10.10.10.10" address. The details are shown in Table
2-3 below, among which:
The IP setting address format is: IPADD0. IPADD1. IPADD2. IPADD3
Default: 192.168.0. IPADD3
The gateway setting format is: GW0. GW1. GW2. GW3
Default: 192.168.0.1
The subnet mask format is: MSK0. MSK1. MSK2. MSK3
Default: 255.255.255.0
Table 2-3 IP address setting
MODBUS address
Bits
Property
Default
Range
Description
170
8
R/W
192
[0,255]
IPADD0
171
8
R/W
168
[0, 255]
IPADD1
172
8
R/W
0
[0, 255]
IPADD2
173
8
R/W
192
[0, 255]
GW0
174
8
R/W
168
[0, 255]
GW1
175
8
R/W
0
[0, 255]
GW2
176
8
R/W
1
[0, 255]
GW3
177
8
R/W
255
[0, 255]
MSK0
178
8
R/W
255
[0, 255]
MSK1
179
8
R/W
255
[0, 255]
MSK2
180
8
R/W
0
[0, 255]
MSK3
2.6. Alarm code
Table 2-4 Alarm code
LED status
Driver status
Green indicator is on for long time
Disabled
Green indicator is flickering
Working normally
One green indicator, one red indicator
Overcurrent
One green indicator, two red indicators
Overvoltage
One green indicator, three red indicators
Internal voltage error
One green indicator, four red indicators
Encoder out of tolerance
alarm