EasyManua.ls Logo

Ruby Tech ES-2310C - Page 186

Ruby Tech ES-2310C
255 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ES-2310C User Manual
Publication date: Aug., 2010
Revision A5
176
diag
diag
Syntax:
diag
Description:
Diag is used to test whether EEPROM, UART, DRAM and Flash is normal or not.
Argument:
None.
Possible value:
None.
Example:
ES-2310C(diag)# diag
EEPROM Test : OK
UART Test : OK
DRAM Test : OK
Flash Test : OK
Loopback
Syntax:
loopback
Description:
For Internal/External Loopback Test.
Argument:
None.
Possible value:
None.
Example:
ES-2310C(diag)# loopback
Internal Loopback Test : OK
External Loopback Test : Port 1 2 3 4 5 6 7 8 9 10 Fail
ping
Syntax:
ping <ip>
Description:
To confirm that whether the remote end-station or switch itself is alive or not.
Argument:
<ip> : IP address or domain name
Possible value:
IP address, e.g. 192.168.2.65 or domain name, e.g. tw.yahoo.com
Example:
ES-2310C(diag)# ping 192.168.1.115
Gateway : 192.168.1.253
192.168.1.115 is alive.

Table of Contents