ES-2310C User Manual
Publication date: Aug., 2010
Revision A5
182
set timer
Syntax:
set timer <range> <join> <leave> <leaveall>
Description:
To set gvrp join time, leave time, and leaveall time for each port.
Argument:
<range> : port range, syntax 1,5-7, available from 1 to 10
<join>: join timer, available from 20 to 100
<leave>: leave timer, available from 60 to 300
<leaveall>: leaveall timer, available from 1000 to 5000
Leave Time must equal double Join Time at least.
Possible value:
<range> : 1 to 10
<join>: 20 to 100
<leave>: 60 to 300
<leaveall>: 1000 to 5000
Example:
ES-2310C(gvrp)# set timer 2-8 25 80 2000
show config
Syntax:
show config
Description:
To display the gvrp configuration.
Argument:
None.
Possible value:
None.
Example:
ES-2310C(gvrp)# show config
GVRP state: Disable
Port Join Time Leave Time LeaveAll Time Applicant Registrar Restricted
---- --------- ---------- ------------- --------------- --------- ----------
1 20 60 1000 Normal Normal Disable
2 20 60 1000 Normal Normal Disable
3 20 60 1000 Normal Normal Disable
4 20 60 1000 Normal Normal Disable
:
:
:
9 20 60 1000 Normal Normal Disable
10 20 60 1000 Normal Normal Disable