Ruijie RG-NBS3200 Series Switches Hardware Installation and Reference Guide Product Overview
14
LED
Panel Identification
State
Meaning
(0.5 Hz)
Ruijie Cloud.
Blinking green (10
Hz)
The switch is being upgraded or initialized.
Solid green
The switch is connected to Ruijie Cloud.
Port mode LED
LED mode
Off
Switching mode.
Solid green
PoE mode.
10/100/1000Base-T
Ethernet port status
LED
124
Off
The port is not connected.
Solid green
The port is connected at a rate of 10/100/1000
Mbps.
Blinking green
The port is receiving or transmitting traffic at a
rate of 10/100/1000 Mbps.
RJ45 port PoE
status LED
124
Off
PoE is not enabled.
Solid green
PoE is enabled. The port is operational.
Blinking green
The port has a PoE fault of overload.
SFP+ port status
LED
25F28F
Off
The port is not connected.
Solid green
The port is connected.
Blinking green
The port is receiving or transmitting traffic.
1.4 RG-NBS3200-48GT4XS
Technical Specifications
Model
RG-NBS3200-48GT4XS
CPU
Built-in CPU, dual-core processor, and 1 GHz
BootROM
N/A
Flash Memory
256 MB
SDRAM
DDRIII 1GB
Optical Module
The copper cable is not supported. See Appendix B.
The supported module type may change at any time. Consult Ruijie Networks for the latest
information.
SFP+ Port
10GBase-R
1000Base-X
Power Supply
AC input
Rated voltage range: 100 V to 240 V
Maximum voltage range: 90 V to 264 V
Frequency: 50/60 Hz
Rated current: 2 A
Input Leakage
Current
3.5 mA
EEE
Supported
PoE
Not supported