Ruijie RG-NBS3200 Series Switches Hardware Installation and Reference Guide Product Overview
13
Press the PoE mode switchover button for over 3 seconds to switch the display mode between PoE mode and port
rate mode.
Back Panel
Figure 1-11 Back Panel of the RG-NBS3200-24GT4XS-P
1. Power cord retention clips
2. Three-hole AC power receptacle
3. Protective earthing terminal
The device relies on the separate protective earthing terminal.
The device installation must be permanently grounded.
The device must be intended to be used in a location with equipotential bonding (such as a telecommunication
center, a dedicated computer room, or a restricted access area).
Heat Dissipation
The RG-NBS3200-24GT4XS-P adopts fans for heat dissipation, thereby ensuring normal operation. You must reserve
10 cm distance space at both sides and the back plane of the cabinet to allow airflow. It is recommended that you clean
the device once every 3 months to avoid dust from blocking vents.