MODEL F7317603
12
2. Basic Setting & Usage
2.1. The Function of PC Board
A. Time of day indicator
Light ondisplay the time of day.
Light flashremind you to reset the time of day if electrical service
interrupted 3 days more (If electrical service interrupted within 3 days,
it doesn’t need to reset the time. )
B. Button lock indicator
Light on, indicate the buttons are locked. At this moment, press any
single button will not work (Under any status, no operation in one
minute, will light on and lock the buttons.)
SolutionPress and hold both and for 5 seconds until the
light off.
C. Program mode indicator
Light onenter program display mode. Use or to view all
values.