10 support@ruptela.com | +370 5 2045030 www.ruptela.com
Remove the measurement head.
Add a thin layer of silicone on both sides of the flange gasket.
Insert the flange gasket onto the flange.
Insert the probe into the tank.
Position the flange according to the previously
made markings.
Screw in the flange bolts using a cordless drill.
Finish screwing in the bolts by hand to avoid
screwing the bolts too much.
Run a security seal wire through the small holes
on the flange.
Screw in
Marked position
Cable direction
Add silicone
Add silicone
Insert