8 Rectification of
malfunctions
8-8
RUTHMANN-Steiger
®
TB270
BA.GB.12-27409-05-07-FTA-jr
fault memory can only be deleted by the Ruthmann-after-sales-service.
8.3.1 Meaning of the fault messages and information about remedy
The following listing should help to analyse malfunctions of the Ruthmann-
Steiger. The codes, possible causes and remedy possibilities mentioned
below should facilitate the search for the source of the faults. Work may
only be carried out by adequately trained expert personnel.
Possible cause
Remedy
Vehicle voltage too low.
Fuse F11 on printed circuit
board for fuses defective.
Safety relay at control system
defective.
Check vehicle battery
Check fuse F 11.
Notify RUTHMANN-after-
sales-service.
Programme switch in main or
control processor system
adjusted wrongly.
Fuse defective.
These switches are sealed
and may only be re-adjusted
by the RUTHMANN-after-
sales-service!
Check fuse.
Vehicle voltage too low.
Program switch of the control
incorrect adjusted. Does not
correspond to model codifica-
tion.
Check vehicle battery.
Notify RUTHMANN-after-
sales-service.
Programme switch adjusted
wrongly.
These switches are sealed
and may only be re-adjusted
by the RUTHMANN-after-
sales-service!
Supply voltage of control sys-
tem wrong.
Control system defective.
Check supply voltage.
Notify RUTHMANN-after-
sales-service.
Supply voltage of control sys-
tem wrong.
Control system defective.
Check supply voltage.
Notify RUTHMANN-after-
sales-service.
LML switch in main or control
processor system adjusted
wrongly.
These switches are sealed
and may only be re-adjusted
by the RUTHMANN-after-
sales-service!

Related product manuals