9.4.5.3 Bearing points / Bolt locking
Bearing points and bolt locking must be checked for:
good condition and cleanness,
wear, fissures and damage,
well-running of bearing,
firm hold of screw fittings of bolt locking
If bolt locks get loose the reason must be ascertained and the fault must
be rectified. We recommend having the repair of defective bearings and
bolt locks carried out by the Ruthmann-after-sales-service or by person-
nel authorized by us accordingly.
Clean bearing points from outside. Do not use high-pressure cleaner
and / or chemical detergents.
Grease DU-bush-bearing points with provided lubrication point (grease
nipple) according to maintenance list.
Cover the DU-bush-bearing points without any grease nipple with oil at
the separation points / contact points.
9.4.5.4 Bearing points with plastic bushes
Visual test concerning condition and cleanness, firm hold, fissures and
damage.
Plastic bushes must be free of grease and oil - do not grease or oil.
Plastic bushes must be free of paint - do not cover with paint.
Clean regularly bearing points from outside (e.g. by means of a cloth).