25
START-UP
• Open all valves and connect the motor.
• Wait a suitable time for tubing auto-priming to take place.
5. MAINTENANCE.
• Clean the pre-lter basket regularly in order to avoid drops in pressure. In order
to avoid possible basket breakage it is recommended not to knock it during the
cleaning process.
• If the pump stops, check that the motor amp consumption during his working is
the same or less than that indicated on the manufacturerʼs specication board, or
failing him, contact the nearest Customer Technical Service.
• If the amp rate is higher, consult the manufacturer.
• Empty the pump in cases where it must remain without use for some time, mainly
in cold countries where there may be danger of freezing.
• To empty the pump, remove the draining plug from the pump body (see explosion
drawing).
• Each time the pre-lter is opened, clean impurities from the joint seating and the
joint itself, to ensure sealing on closure of the cover. (Fig.5).
6. DISMANTLING
• The motor unit may be dismantled from the pump body without needing to
disconnect the pumpʼs suction and impulsion tubing.
• To disconnect the motor unit from the pump body, remove the screws that join them
(see explosion drawing).