7- FUNCTION / USE AND
PROGRAMMING
INTRODUCTION
The programming software permits the checking of the
following operations:
- handling of 1 - 2 coffee units
- control of four different coffee doses for each unit
- simultaneous function of both coffee and tea units
- volumetric check on coffee measures
- simulated measure programming
- filling level check and control
- system supervision through alarms
- continuos, delivery time-out and further functions
- serial connection with accounting devices
6.5 Replacement of the thermostat to
reduce the coffee dispensing
group temperature.
Remove cup heating bowl (1). Disconnect group thermostat
(2) (Code WGADM1561 T 103°C) and replace it with
the lower temperature thermostat (Code WGADM1736
T 98°C), included in the machine equipment.
T1 single espresso coffee
T2 double espresso coffee
T3 single long coffee
T4 double long coffee
T5 Programming/continuos
Keyboard symbols:
fig. 9