EasyManua.ls Logo

Safewatch QuickConnect Plus - Zone Sounds and Timing

Safewatch QuickConnect Plus
24 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
- 4 -
Data Field Display Function& Programming Options [ ] = Programmed Table 1 Default Values
ZONE SOUNDS AND TIMING (31–
39)
31
3131
31
SINGLE
SINGLE SINGLE
SINGLE
ALARM
ALARM ALARM
ALARM
SND
SNDSND
SND
Single Alarm Sounding/Zone
UL installations = 0
† [0]
0 = Alarm Sounding Per Zone will be the same as the Swinger Shutdown” set in field *92;
1 = yes, limit once per arming period (also applies to long range radio output if “0” is
selected in 91 field)
32
3232
32
FIRE
FIRE FIRE
FIRE
SND
SNDSND
SND
TIMEOUT
TIMEOUT TIMEOUT
TIMEOUT
Sounder Timeout
† [0]
0=timeout; 1=no timeout
33
3333
33
ALRM
ALRM ALRM
ALRM
SND
SND SND
SND
TIMEOUT
TIMEOUTTIMEOUT
TIMEOUT
Alarm Bell Timeout
UL installations = 1 (4 min) minimum
† [1]
0 = none; 1=4 min; 2=8 min; 3=12 min; 4 = 16 min
34
3434
34
EXIT
EXIT EXIT
EXIT
DELAY
DELAYDELAY
DELAY
TIME
TIME TIME
TIME
Exit Delay
UL installations = 60 seconds max.
|
[60]
45-96 = exit delay time (in seconds)
97 = 120 seconds
Note: The control validates the data entered in this field. If the selection is not valid the control will
emit a single long beep indicating that the selection has been rejected. The control replaces
the selection with the default value “60”, which is displayed on the keypad, and advances to
the next field.
SIA: Must be set to a minimum of 45 seconds.
35
3535
35
ENTRY
ENTRY ENTRY
ENTRY
DELAY
DELAYDELAY
DELAY
1
1 1
1
Entry Delay 1 (zone type 01)
UL installations = 45 seconds max.
|
† [30]
30-96 = entry delay 1 time (in seconds)
97 = 120 seconds
98 = 180 seconds
99 = 240 second
Note: The control validates the data entered in this field. If the selection is not valid the control will
emit a single long beep indicating that the selection has been rejected. The control replaces
the selection with the default value “30”, which is displayed on the keypad, and advances to
the next field.
SIA: The entry delay must be set to a minimum of 30 seconds. The sum of entry delay 1 entered in
Field *35 and the burglary abort window entered in *50 should not exceed 1 minute.
36
3636
36
ENTRY
ENTRY ENTRY
ENTRY
DELAY
DELAY DELAY
DELAY
2
22
2
Entry Delay 2 (zone type 02)
UL installations = 45 seconds max.
|
† [30]
30-96 = entry delay 2 time (in seconds)
97 = 120 seconds
98 = 180 seconds
99 = 240 second
Note: The control validates the data entered in this field. If the selection is not valid the control will
emit a single long beep indicating that the selection has been rejected. The control replaces
the selection with the default value “30”, which is displayed on the keypad, and advances to
the next field.
SIA: The entry delay must be set to a minimum of 30 seconds. The sum of entry delay 2 entered in
Field *36 and the burglary abort window entered in *50 should not exceed 1 minute.
38
3838
38
CON
CONCON
CONF
FF
F
ARM
ARMARM
ARM
ING
INGING
ING
DING
DINGDING
DING
Confirmation of Arming Ding
Note: Confirmation ding only sounds when Safewatch QuickConnect Plus is Armed Away or disarmed
after being Armed Away. If Safewatch QuickConnect Plus is armed by RF button (key fob), a
confirmation ding occurs immediately after arming regardless of field
38 settings. If Safewatch
QuickConnect Plus is disarmed by RF button (key fob), additional disarming confirmation ding occurs
immediately after disarming and is longer than arming confirmation ding.
† [0]
0 =
no arming confirmation ding after arming system by Safewatch QuickConnect Plus keypad or RF
keypad
;
1 = arming confirmation ding after arming system by Safewatch QuickConnect Plus keypad
or RF keypad;
2 = arming confirmation ding after arming from RF keypad only
† Entering a number other than the one specified may give unpredictable results.