Charging temperature
high protection
Battery temperature too
high
Wait until battery
temperature decreased and
the error is clear
Discharging
temperature low
protection
Battery temperature too
low, disconnect relay to
stop discharging
Wait until battery
temperature increased and
the error is clear
Discharging
temperature high
protection
Battery temperature too
high
Wait until battery
temperature decreased and
the error is clear
1. Cathode or anode
relay is adhesive
2. Cathode or anode
relay is unable to close
1. Pre-charge relay
damaged
2. Pre-charge resistor
open-circuit
3. BMS damaged
1. Replace pre-charge relay
2. Replace pre-charge
resistor
3. Replace BMS
Battery module has
electricity leakage
BMS supplier
incompatibility
BMS of battery module
and battery control unit
are incompatible
Check if the model of
battery module and battery
control unit are compatible
Battery cell supplier
impartibility
Supplier of battery
module and battery cell
are incompatible
Check if the model of
battery module is correct
Battery cell
incompatibility
Battery cells are
incompatible
Check if the model of
battery module is correct
Battery module voltage
are inconsistent
Check if the model of
battery module is correct
1. Circuit breaker is
open
2. Circuit breaker
auxiliary contact error
Temperature difference
is too wide
1. Temperature sensor
error
2. Battery life span
1. Check if temperature
sensor cable is in poor
contact
Voltage difference is
too wide
1. Sensor cable is loose
2. Battery life span
1. Check if voltage sensor
cable is in poor contact
2. Replace BMS
Voltage difference is
too wide
1. Sensor cable is loose
2. Battery life span
1. Check if voltage sensor
cable is in poor contact
2. Replace BMS
BMS over temperature
protect
1. Ambient temperature
is high
2. Overload
1. Check if ambient
temperature is high
2. Check if overloaded
Check if the cable
connected correctly
Warranty