5.3.3 R5-7K/8K-S2AC Side Electrical Connection
Screw off the screws at the AC output wire cover and take out the cover.
Penetrate the AC cable of which the insulation layers has been peeled off through
the AC waterproof locking screw hole of the cover. Lock L wire, N wire and PE
wire tightly as per the marked connection positions on the interface board.
Fig. 5.8 Connecting the cable
After fixing the cover at the AC output wire terminal with screws, tighten up
the AC waterproof nut.
Fig. 5.9 Tighten up AC interface protective cover and the locker