R6 Series
- 17 -
R6-5K/6K/8K/10K/15K-T2-32-LV
Model
R6-5K-T2-
32-
LV
R6-6K-T2-32-
LV
R6-8K-T2-32-
LV
R6-10K-T2-32-
LV
R6-15K-T2-32-
LV
Input (DC)
Max. PV Array Power [Wp]@STC
7500
9000
12000
15000
22500
Max. Input Voltage [V]
1100
MPP Voltage Range [V]
180-1000
Nominal Input Voltage [V]
600
Start-up Voltage [V]
200
Max. Input Current [A]
32/32
Number of MPP Trackers
2
Number of Strings per MPP Tracker
2/2
Output (AC)
Rated AC Output Power [W]
5000
6000
8000
10000
15000
Max. Apparent Power [VA] *
1
5500
6600
8800
11000
15000
Rated AC Output Current [A]@230Vac
13.1
15.7
21
26.2
39.4
Max. AC Output Current [A]
14.4
17.3
23.1
28.9
39.4
Nominal AC Voltage/ Range [V]
127V(F-N)/220V(F-F); 101.6-139.7(F-N)
Nominal AC Grid Frequency/ Range [Hz]
50, 60/44-55, 54-65
Total Distortion Harmonic [THDi]
< 3%
Power Factor
0.8 leading0.8 lagging
Feed-in Phases/AC Connection Phases
3/3
Efficiency
Max. Efficiency
98.8%
Euro Efficiency
98.5%
Protection
DCI Monitoring
Integrated
GFCI Monitoring
Integrated
Grid Monitoring
Integrated
AC Grounding Detection
Integrated
AC Short-Circuit Protection
Integrated
DC Insulation Resistance Detection
Integrated
DC Surge Protection
Type III
AC Surge Protection
Type III

Other manuals for SAJ R6-40K-T4-32

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SAJ R6-40K-T4-32 and is the answer not in the manual?

SAJ R6-40K-T4-32 Specifications

General IconGeneral
BrandSAJ
ModelR6-40K-T4-32
CategoryInverter
LanguageEnglish

Related product manuals