    What to do if my SAJ R6-50K-T4-32 Inverter shows a High Temperature Error?
    • I
      ivanortegaAug 8, 2025
      If your SAJ Inverter displays a High Temperature Error, first check if the radiator is blocked. Also, verify that the inverter is operating within an appropriate temperature range (not too high or too low). If both the radiator and temperature conditions are normal, it is recommended to contact your distributor or SAJ technical support for further assistance.
  • U
    umartinAug 13, 2025
    What to do if I see a Current Sensor Error on my SAJ R6-50K-T4-32?
    • T
      Timothy Murillo MDAug 13, 2025
      If you frequently encounter a Current Sensor Error with your SAJ Inverter, it is recommended to contact your distributor or call SAJ technical support for assistance.
  • B
    Brian WilliamsAug 17, 2025
    What to do if my SAJ R6-50K-T4-32 displays a Relay Error?
    • M
      Michael StevensonAug 18, 2025
      If a Relay Error occurs frequently with your SAJ Inverter, please contact your distributor or call SAJ technical support.
  • Q
    qhorneAug 22, 2025
    What should I do if my SAJ R6-50K-T4-32 shows a Master Lost Communication error?
    • W
      williamgibsonAug 22, 2025
      If you frequently encounter a Master Lost Communication error with your SAJ Inverter, it is recommended to contact your distributor or call SAJ technical support for assistance.
  • P
    Pamela SanchezAug 27, 2025
    What should I do if my SAJ R6-50K-T4-32 is showing a Storer Error?
    • S
      Scott RodriguezAug 28, 2025
      If a Storer Error occurs frequently with your SAJ Inverter, please contact your distributor or call SAJ technical support.
  • C
    Cristian BrooksSep 1, 2025
    What to do if SAJ Inverter shows AC Voltage Error?
    • C
      Christina HughesSep 1, 2025
      To address an AC Voltage Error on your SAJ Inverter, first, check the voltage of the grid and ensure the connection between the inverter and the grid is secure. Verify the on-grid standard settings of the inverter. If the grid voltage is too high, consult with local grid workers about adjusting the voltage or changing the regulated voltage value. If the grid voltage is within the allowed range and the error persists, contact your distributor or SAJ technical support.

Summary

CHAPTER 6 DEBUGGING INSTRUCTIONS

CHAPTER 7 FAULT CODE AND TROUBLESHOOTING

SAJ WARRANTY POLICY

Chapter 1 Safety Precautions

1.2 Safety Instructions

Provides critical safety warnings and precautions for inverter use.

Chapter 2 Preparation

2.1 Safety Instructions

Outlines essential safety guidelines before inverter operation.

Chapter 3 Product Information

Chapter 4 Instructions for installation

4.1 Safety Instructions

Provides essential safety guidelines for inverter installation.

4.3 Installation Method and Position

Determines the appropriate mounting method and location for the inverter.

4.4 Mounting Procedure

Step-by-step guide for mounting the inverter.

Chapter 5 Electrical Connection

5.1 Safety Instruction for Hot-line Job

Safety precautions for electrical connections involving live circuits.

5.3 AC Connection

Instructions and specifications for connecting the inverter to AC power.

Chapter 7 FAULT CODE AND TROUBLESHOOTING

SAJ R6-50K-T4-32 Specifications

General IconGeneral
Rated Power50 kW
Max. DC Input Power75 kW
Maximum PV Input Power75 kW
Max. DC Voltage1100 V
Maximum PV Input Voltage1100 V
Start-up Voltage200 V
MPPT Voltage Range200-1000 V
Number of MPPTs4
Max. Input Current per MPPT32 A
Maximum Input Current per MPPT32 A
Rated AC Output Power50 kW
AC Rated Output Power50 kW
Max. AC Apparent Power55 kVA
Rated AC Voltage400 V
AC Output Voltage Range310-480 V
AC Voltage Range310-480 V
Rated Grid Frequency50/60 Hz
AC Output Frequency50/60 Hz
THDi<3%
Power Factor0.8 leading to 0.8 lagging
Max. Efficiency98.7%
Maximum Efficiency98.7%
DC SwitchYes
Protection LevelIP66
Operating Temperature Range-25°C to +60°C
Humidity Range0-100% (non-condensing)
CommunicationRS485, WiFi, Ethernet