14
P0 Standard Function Parameters
Function
Code
Parameter
Name
Setting Range Default Property
P0-03
Main frequency
source X
selection
0: Digital setting (preset frequency
P0-08, press UP/DOWN to modify,
non-retentive at power failure)
1: Digital setting (preset frequency
P0-08, press UP/DOWN to modify,
retentive at power failure)
2: AI1
3: Panel potentiometer
4: External panel potentiometer
5: HDI pulse setting (DI5)
6: Multi-command
7: Simple PLC
8: PID
9: Communication setting
3 ★
P0-04
Auxiliary
frequency source
Y selection
The same as P0-03 (Main
frequency source X selection)
0 ★
P0-05
Selection of Y
range of auxiliary
frequency source
in superposition
0: Relative to maximum frequency
1: Relative to main frequency X
0 ☆
P0-06
Selection of Y
range of auxiliary
frequency source
in superposition
0% ~ 150% 100% ☆
6.1 Brief introduction of function code