Pump installation and warranty
guide for the CT range of pumps
CT Force, CT Xtra, and CT Bathroom
ISSUE M
Aug 2022
Models shown:
CT FORCE 15TU
CT50+ Xtra
This document should be given to the end user and retained for future reference.
Should you need to contact Salamander Pumps you will need the below information.

Questions and Answers

  • J
    Jessica BrooksAug 16, 2025
    Why won't my Salamander Pumps CT FORCE 30 TU Water Pump start?
    • R
      rothvincentAug 16, 2025
      If your Salamander Pumps Water Pump isn't starting, several factors could be at play. Check the power supply, fuse, and circuit breaker to ensure they are functioning correctly. Also, verify that the inlet and outlet connections are plumbed correctly and all valves are open. Insufficient gravity flow, debris under the flow switch, or a float sticking in the outlet could also be the cause. Make sure the inlet filters aren't blocked and that a minimum flow rate of 2l/min is achieved on both the hot and cold water supplies. Clear any debris from the outlet area and ensure the flow switch sits in the lowest position.
  • S
    sheila73Aug 18, 2025
    What to do if my Salamander Pumps CT FORCE 30 TU Water Pump has reduced or intermittent flow?
    • A
      Amanda LaneAug 19, 2025
      If you're experiencing reduced or intermittent flow with your Salamander Pumps Water Pump, several issues could be responsible. First, ensure that an appropriate anti-aeration flange is fitted. Check for blocked inlet filters and ensure that all filters and the shower head are free from debris. Confirm that all AV couplers are straight and not bent or distorted, as they can restrict flow. Air in the system or the wrong size pump for the system could also be culprits. If there is air in the system, run the system on full hot with the pump switched off (gravity only) for several minutes. Check that the cold water storage and refill rate are adequate. Also, consider reducing the cylinder thermostat setting to a maximum of 60°C or fitting a HWS/TMV if the hot water temperature is set too high.
  • K
    krochaAug 21, 2025
    How to reduce noise from a Salamander Pumps Water Pump?
    • K
      Kevin FryAug 22, 2025
      If your Salamander Pumps Water Pump is generating excessive noise, there are a few potential causes to investigate. Air in the system could be the issue; refer to the instructions for bleeding the system. Ensure that the rubber feet are properly fitted to the pump to minimize vibration against the surface it's resting on. Also, check that all AV couplers are straight and not bent or distorted, as they can cause vibration.
  • Y
    yandersonAug 25, 2025
    Why does my Salamander Pumps CT FORCE 30 TU Water Pump start when all outlets are closed?
    • D
      David WashingtonAug 26, 2025
      If your Salamander Pumps Water Pump starts even when all outlets are closed, this typically indicates either a leak in the system or an outlet that isn't fully closed. Check thoroughly for any leaks in the pipework. Ensure that all outlets are fully closed or properly capped, and that there are no dead legs in the pipework.
  • I
    iwilliamsAug 28, 2025
    What causes a Salamander Pumps Water Pump to leak?
    • C
      Christopher BaileyAug 28, 2025
      If your Salamander Pumps Water Pump is leaking, several factors could be responsible. Check if the pump has been exposed to mains water pressure; if so, fit a break cistern or remove it from the mains supply. Chemical damage or exposure to excessive temperature can also cause leaks. Ensure that the pump hasn't come into contact with any chemical substances like solder flux and verify that effective temperature control is in place using a cylinder thermostat or HWS/TMV valve. Also, check that the leak isn't originating from fittings in the pipework above the pump.
  • T
    Timothy TranAug 30, 2025
    Why is my Salamander Pumps CT FORCE 30 TU not starting?
    • J
      Jason PerezAug 30, 2025
      Your Salamander Pumps Water Pump might not start due to several reasons: * Insufficient gravity flow: Verify the pump's suitability for your setup, ensuring it's not in a negative head installation. Check that the inlet filters are not blocked and that the flow rate meets the minimum requirement of 2l/min on both hot and cold water supplies. * Incorrect inlet/outlet connections: Make sure the connections are plumbed correctly and all valves are open. * Electrical issues: Check the power supply, fuse, and circuit breaker. * Debris under the flow switch: Remove the outlet hoses to check that the flow switch is in its lowest position. * Float sticking in the outlet: Ensure there's no debris in the outlet area.
  • K
    Kimberly HannaSep 6, 2025
    Why is Salamander Pumps Water Pump noisy?
    • T
      Timothy LewisSep 6, 2025
      A noisy Salamander Pumps Water Pump can be attributed to: * Air in the system: Refer to the instructions for dealing with air in the system. * Pump vibrating on the surface: Ensure the rubber feet are fitted to the pump. * AV couplers causing vibration: Check that all AV couplers are straight and not bent or distorted.
  • J
    Jonathan RoblesSep 8, 2025
    What to do if Salamander Pumps CT FORCE 30 TU Water Pump starts with all outlets closed?
    • C
      Christopher TateSep 8, 2025
      If your Salamander Pumps Water Pump starts when all outlets are closed: * Check for leaks in the system. * Ensure all outlets are fully closed or capped, and there are no dead legs in the pipework.
  • R
    Ryan BruceSep 12, 2025
    Why is my Salamander Pumps CT FORCE 30 TU Water Pump leaking?
    • M
      Mrs. Theresa HernandezSep 12, 2025
      If your Salamander Pumps Water Pump is leaking, consider these potential causes: * Pump exposed to mains water pressure: Fit a break cistern or remove the pump from the mains supply. * Pump suffered chemical damage: Ensure the pump hasn't come into contact with chemical substances like solder flux. * Pump exposed to excessive temperature: Check if effective temperature control is fitted (cylinder thermostat or HWS/TMV valve). * Unsure if the pump is leaking: Verify the leak isn't coming from a fitting in the pipework above the pump.
  • M
    Mrs. Robin CarrollDec 3, 2025
    What to do if Salamander Pumps CT FORCE 30 TU Water Pump has reduced or intermittent flow?

    Summary

    Important - read this first!

    Safety in Operation

    Installation instructions

    Step 1: Pump location

    Guidance on selecting the optimal location for the pump.

    Step 2: Connecting the pump

    Instructions for connecting the pump using AV couplers and fittings.

    Step 3: Electrical installation

    Details on connecting the pump to the electrical supply and wiring regulations.

    Helpful Pump Wise guidelines

    Stored hot water temperature

    General specifications - CT FORCE

    General specifications - CT Xtra & CT Bathroom

    Technical specifications - CT Force

    Technical Specifications - CT Xtra

    Technical Specifications - CT Xtra H & HU, CT Bathroom B & BU

    Trouble Shooting

    Pump will not start

    Troubleshooting steps for when the pump fails to start.

    Reduced;intermittent flow

    Diagnosing and resolving issues with reduced or intermittent flow.

    Warranty

    To the installer

    The Scope of the Warranty

    Defines the warranty coverage and exclusions for the product.

    Terms and conditions

    Outlines the essential terms and conditions for warranty enforceability.

    The Warranty periods

    Details the specific warranty durations for different pump models.

    Salamander Pumps CT FORCE 30 TU Specifications

    General IconGeneral
    Pump TypeCentrifugal
    Head30 meters
    Maximum Flow Rate50 liters per minute
    Voltage230 V
    Frequency50 Hz
    Weight8.5 kg
    ApplicationBoosting water pressure in domestic and commercial applications